2H0/2HZ
1-2-13
5. Remove two screws and remove the scan-
ner right cover.
6. Cut out the aperture plate on the upper right
cover using nippers.
7. Pull the key counter wire out.
Figure 1-2-16
8. Seat the fook of the key counter cover
retainer in the aperture in the right upper
cover.
9. Fit the key counter cover retainer using two
screws.
Figure 1-2-17
Screw
Screw
Scanner
right cover
Right upper
cover
Aperture
Key counter wire
Hook
Key counter
cover retainer
(302GR03010)
M4 x 20 screw
(7BB100420H)
M3 x 8 screw
(5MBTP+R)
Aperture
Right
upper cover