2H0/2HZ
1-5-35
9. Remove the claw and remove the inner
cover lid.
10. Remove three connectors.
11. Pull the developing lever.
Figure 1-5-64
12. Remove the screw and remove the drum
unit.
13. Replace the drum unit and install the unit.
When the drum unit is replaced, perform
maintenance mode U110 to clear the
counter value (see page 1-3-42).
Figure 1-5-65
Inner cover lid
Inner cover lid
Claw
Developing lever
Connectors
Drum unit
Screw
Y108620-5 Service Manual