2H0/2HZ
1-4-5
Paper
conveying
section
30
Misfeed in registration/
transfer section
The registration switch (RSW) does not turn off within
specified time of the feed switch 1 (FSW1) turning off.
1314 ms
The registration switch (RSW) does not turn off within
specified time of the feed switch 1 (FSW1) turning on.
1100 ms
The registration switch (RSW) does not turn on within
specified time of the feed switch 1 (FSW1) turning on.
1100 ms
The registration switch (RSW) does not turn off within
specified time of the MP feed switch (MPFSW) turning
off.
1686 ms
Fuser
section
40
Misfeed in fuser section
(MP tray)
41
Misfeed in fuser section
(cassette 1)
42
Misfeed in fuser section
(cassette 2)
43
Misfeed in fuser section
(optional cassette 3)
44
Misfeed in fuser section
(optional cassette 4)
47
Misfeed in fuser section
(duplex section)
The eject switch (ESW) does not turn on within specified
time of the registration clutch (RCL) turning on.
2321 ms
The feedshift switch (FSSW) does not turn on within
specified time of the registration clutch (RCL) turning on.
1336 ms
Eject
section
50
Misfeed in eject section
The eject switch (ESW) does not turn off within specified
time of the registration switch (RSW) turning off.
2321 ms
The eject switch (ESW) does not turn off within specified
time of the registration clutch (RCL) turning on.
2321 ms
51
Misfeed in job separa-
tor eject section
The job separator eject switch (JBESW) does not turn on
within specified time of the feedshift switch (FSSW) turn-
ing on.
1350 ms
The job separator eject switch (JBESW) does not turn off
within specified time of the feedshift switch (FSSW) turn-
ing off.
714 ms + Paper
length
The job separator eject switch (JBESW) does not turn off
within specified time of the feedshift switch (FSSW) turn-
ing on.
1350 ms
Feedshift
section
52
Misfeed in feedshift
section
The feedshift switch (FSSW) does not turn on within
specified time of the start of eject motor (EM) reverse
rotation.
1121 ms
During paper switchback operation, the feedshift switch
(FSSW) does not turn off within specified time of the its
turning on.
4514 ms
The feedshift switch (FSSW) does not turn off within
specified time of the its turning on.
4514 ms
The feedshift switch (FSSW) does not turn off within
specified time of the registration clutch (RCL) turning on.
2321 ms
Section
Description
Conditions
Specified time
Y108620-5 Service Manual
Содержание d-Copia 2500MF
Страница 1: ...d Copia 2500MF d Copia 3000MF Digital Copier SERVICE MANUAL Code Y108620 5...
Страница 4: ...This page is intentionally left blank...
Страница 10: ...This page is intentionally left blank...
Страница 14: ...2H0 2HZ This page is intentionally left blank...
Страница 20: ...2H0 2HZ 1 1 6 This page is intentionally left blank Service Manual Y108620 5...
Страница 258: ...2H0 2HZ 2 1 20 This page is intentionally left blank Service Manual Y108620 5...
Страница 296: ...UPDATING STATUS DATE UPDATED PAGES PAGES CODE 10 2007 1ST EDITION 296 Y108620 5...