Minimum cord size (AWG) required based on amperage draw and length of the cord:
Amps
Power Cord Length
25 feet
50 feet
75 feet
100 feet
> 100 feet
< 5
16
14
14
14
NR
5 to 8
14
14
14
12
8 to 12
14
14
12
10
12 to 15
12
12
10
10
15 to 20
10
10
10
NR
21 to 30
10
NR
NR
NR
*NR: Not Recommended
WARNING
Use properly sized wires that meet or exceed the power requirement of your
machine. Using undersized wires may cause overheating and increase the risk of fire
and machine damage.
WARNING
Improper copper-aluminum wire connection is a fire hazard. If the power circuit
available uses aluminum wires, use certified CU/AL wire connectors.
Содержание 4430.201 M-4430
Страница 2: ......
Страница 10: ...10 Page Oliver Machinery 4430 Planer Identification...
Страница 11: ...4430 Planer OLIVERMACHINERY NET 11 Page...
Страница 12: ...12 Page Oliver Machinery 4430 Planer...
Страница 38: ...38 Page Oliver Machinery 4430 Planer Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6...
Страница 50: ...50 Page Oliver Machinery 4430 Planer Wiring Diagram...
Страница 51: ...4430 Planer OLIVERMACHINERY NET 51 Page Parts List Table Assembly...
Страница 52: ...52 Page Oliver Machinery 4430 Planer Cabinet Assembly...
Страница 53: ...4430 Planer OLIVERMACHINERY NET 53 Page Motor Mount Assembly...
Страница 54: ...54 Page Oliver Machinery 4430 Planer Headstock Assembly...
Страница 55: ...4430 Planer OLIVERMACHINERY NET 55 Page Gearbox Assembly Cover and Dust Hood Assembly...
Страница 62: ...62 Page Oliver Machinery 4430 Planer Maintenance Record Date Task Operator...
Страница 63: ...4430 Planer OLIVERMACHINERY NET 63 Page Notes...