48 |
Page
Oliver Machinery
4265 Jointer
Troubleshooting
Problem
Possible Cause
Possible Solution
Machine does not start.
Machine is not
connected to a power
source.
1.
Make sure machine is plugged in, or power
disconnect is at the ON position.
2.
Check electrical panel for tripped circuit
breaker or blown fuse.
3.
Ensure all electrical connections have good
contacts.
Low voltage / current. Have an electrician to check/repair the power
circuit.
Faulty switch/motor/
capacitor.
Contact customer service for further assistance.
Machine trips thermal
protection / circuit
breaker, or blow fuses.
Machine is undersized
for the operation.
Reduce depth of cut and/or feed rate.
Workpiece moisture
level is too high.
Only joint wood with moisture level below 20%.
Machine is jammed.
Make sure cutterhead is not jammed by
woodchips. Check dust chute and clear
blockages.
Too much load on a
circuit.
Make sure power circuit is sized for this
machine. If the same circuit is shared, ensure the
circuit is sized to supply power for all items in
the circuit.
Motor/capacitor
issue.
Contact customer service for further assistance.
Machine stalls during
operation.
Machine is undersized
for the operation.
Reduce depth of cut. Lower feed rate.
Dull cutters
Rotate/replace cutter inserts.
Belt slipping
Clean belt and the pulleys. Adjust belt tension.
Motor/capacitor
issue.
Contact customer service for further assistance.
Machine stopped during
operation.
Thermal overload
protection triggered.
Hit STOP button and wait for at least 3 minutes.
When machine is cooled down, overload
protection will reset automatically. Reduce
depth of cut and feed rate before continue.
Outfeed table is
stuck/difficult to adjust.
Outfeed table is
locked.
Loosen the locking cap screw before adjusting
the outfeed table.
Digital readout not
functional.
Dead battery.
Replace battery.
Содержание 4265
Страница 2: ......
Страница 10: ...10 Page Oliver Machinery 4265 Jointer Identification...
Страница 11: ...4265 Jointer OLIVERMACHINERY NET 11 Page...
Страница 51: ...4265 Jointer OLIVERMACHINERY NET 51 Page Wiring Diagram For Stock 4265 101 4S 230V 1Ph...
Страница 52: ...52 Page Oliver Machinery 4265 Jointer For Stock 4265 102 4S 230 460V 3Ph...
Страница 53: ...4265 Jointer OLIVERMACHINERY NET 53 Page Parts List Fence Assembly...
Страница 54: ...54 Page Oliver Machinery 4265 Jointer Table and Cutterhead Assembly...
Страница 55: ...4265 Jointer OLIVERMACHINERY NET 55 Page Base Assembly...
Страница 56: ...56 Page Oliver Machinery 4265 Jointer Motor and Cabinet...
Страница 66: ...66 Page Oliver Machinery 4265 Jointer Maintenance Record Date Task Operator...
Страница 67: ...4265 Jointer OLIVERMACHINERY NET 67 Page Notes...