Pellematic settings
74
Hyst Flue Gas Temp
The flue gas temperature must be above the boiler temperature plus Hyst Flue Gas
Temp for a successful ignition.
Min Flue Gas TempMax
Flue Gas Temp
Is the minimum and maximum limit of the flue gas temperature for the ignition.
27.3 Full power settings
Full power settings
is in the menu Pellematic
Full power settings has following menu items:
• Fuel Adjustment
• De+
• Air Flow Rate ++
• Flue Gas Fan ++
The additional menu items
Full power settings
are for the ÖkoFEN Service technician. They are present after
entering the code:
Fuel Adjustment
The run duration of the burner auger is calculated from the boiler controller. It
is independent from the rated power and the boiler set temperature and is set
automatically. The burner motor is then controlled accordingly. You can raise or
reduce the run time, calculated by the boiler controller, respective in 10 steps.
De+
Adjustment of the run time of the burner motor in the Full Power mode. Expressed
in tenths of a second.
Air Flow Rate ++
Adjusting the speed of the combustion air fan in the Full Power mode.
Flue Gas Fan ++
Adjusting the flue gas fan in the Full Power mode.
Operating manual Pelletronic Touch
E1389EN 2.0