44871001TH Rev.6
4-57
Oki Data CONFIDENTIAL
4.REPLACEMENT OF PARTS
4.2.30 Frame-Assy-Retard, Spring-Retard
(1) Remove the cassette.
(2) Open the Retard-Cover by pushing two tabs in the directions of the arrows.
(3) Remove Frame-Assy-Retard by pushing it in the direction of the arrow.
(Spring-Retard
is removed together.)
(4 ) Installing is performed by the inverse procedure with removing.
Retard-Cover
Tab