44871001TH Rev.6
4-41
Oki Data CONFIDENTIAL
4.REPLACEMENT OF PARTS
4.2.18 Fuser Assy
Note!
Replace the Fuser-Assy by Assy unit.
It is forbidden for disassembling the Fuser-Assy, also, reusing the
disassembled Fuser-Assy.
(1) Remove the Frame Assy TR. (Refer to 4.2.11)
(2) Remove the Scanner unit. (Refer to 4.2.8)
(3) Remove the Cover Assy Stacker. (Refer to 4.2.16)
(4) Remove the screw (Silver) and remove the FG-Cable from Guide Cable .
(5) Remove the screw (Black) and the screw (Silver) , and remove FG_Film
(FFC) from Guide Cable .
(6) Remove the Guide Cable .
①
②
③
④
⑤
⑥
Push
③
③
④
⑤