Oki Data CONFIDENTIAL
6. MAINTENANCE MENUS
44871001TH Rev.6
6-2
6.1 Maintenance Menu
Note!
The initial Password is set to "000000" (six zeros).
Item1
Item2
Item3
Item4
Item5
Value
Default
value
ODA
Default
value
OEL
Default
value
JP
Notes
Password
************
Enter the password for accessing the maintenance menu.
6 to 12 characters (numerals and lower-case alphabetic characters) may be entered.
System
Mainte-
nance
OKIUSER
*MPS mode:
MPS. Not
shown during
maintenance.
ODA
OEL
APS
JP1
JPOEM1
OEMA
OEML
Set the destination.
JPOEM1 : OEM for Japan
OEMA
: OEM for overseas, with A4 as default size
OEML
: OEM for overseas, with Letter as default size
Device reboots automatically after exiting the menu.
Displayed under the following conditions:
"However, operation when JP1/JPOEM/OEMA/OEML is chosen is not guaranteed.
The display condition of the menu is following two.
①
"System Maintenance" - "When "OKIUSER" is other than JPOEM1, OEMA or
OEML
②
"Manufacturer" is "OKI DATA CORP".
Format SD
Memory Card
*Shown only
when an
SD card is
connected
Execute
Formats the SD card.
A confirmation message is displayed when the Enter switch is pressed.
When "No" has been selected, the system returns to the previous menu. When
"Yes" has been selected, the menu is exited and formatting of the inserted SD card
begins.
Displayed under the following conditions:
SD card inserted ("Boot Menu" - "Storage Setup" - "Enable SD Card" is Yes)
Format Flash
Memory
Execute
Formats flash ROM memory.
When this command is executed, the menu is exited and formatting of the resident
(onboard) flash device begins.
Use of this command is strictly prohibited (contact design before use)
Reset Admin
Password
Execute
Returns the administrator password to the factory default value.
All Reset
*MPS mode:
MPS. Not
shown during
maintenance.
Execute
Returns the content of EEPROM, flash, and the HDD to their factory default values.
When this command is executed, the following confirmation message is displayed:
"This change will reboot the device automatically. Proceed?"
When "No" has been selected, the system returns to the previous menu. When
"Yes" has been selected, the menu is exited immediately and then, after rebooting,
reset processing begins.
See the "format scope" sheet for the scope of formatting.
Service Menu
When the equipment is in standby mode, access the password entry screen by pressing [Setting]
→
[#]
→
[0]
→
[1]
→
[0]
→
[3]
→
[*].
Содержание MB461MFP
Страница 1: ...MB461 MB471 MB491 MB491 MB491 LP MPS4200mb MPS4700mb Maintenance Manual 031314C ...
Страница 72: ...Oki Data CONFIDENTIAL 44871001TH Rev 6 3 21 3 MFP INSTALLATION Sample MB471 Sample MB491 ...
Страница 103: ...44871001TH Rev 6 4 25 Oki Data CONFIDENTIAL 4 REPLACEMENT OF PARTS 4 2 8 13 LCD assy 1 Remove the LCD assy ...
Страница 114: ...44871001TH Rev 6 4 36 Oki Data CONFIDENTIAL 4 REPLACEMENT OF PARTS ...
Страница 138: ...Oki Data CONFIDENTIAL 5 LUBRICATING POINT 5 1 Lubrication point 5 2 ...
Страница 261: ...Oki Data CONFIDENTIAL 44871001TH Rev 6 8 69 8 TROUBLESHOOTING PROCEDURES Figure 7 4 Fuser Assy Contact plate ...
Страница 281: ...Oki Data CONFIDENTIAL 10 APPENDIX 10 1 List of Initialized range 10 2 10 2 Maintenance Manual for Second Tray unit 10 9 ...