Oki Data CONFIDENTIAL
44871001TH Rev.6
6-26
6. MAINTENANCE MENUS
Display
Setting value
Operation at the
setting value
Function
TONER SENSOR
ENABLE
Detects
Valid/Invalid of toner sensor
operation.
DISABLE
Not to detect
ID UNIT CHECK
ENABLE
Checks
Valid/Invalid of ID installation
check operation.
DISABLE
Not to check
DRUM OVER LIFE
STOP
Not to continue The restriction on extending
the life of toner-related items
five times is lifted.
CONTINUANCE To continue
WR POINT REV
TBL=**H±*.***mm
00H~FFH
Correction
value
The correction value is added
to the existing write-down
position.
BOTTOM WRT POINT
TBL=**H±*.***mm
00H~FFH
Cut value
Amount of cut at the rear end
of a paper is set.
T1 DOT SHIFT
**H mm
0H-FH
Correction
value
The dot shift amount for
TRAY1 is set.
T2 DOT SHIFT
**H mm
0H-FH
Correction
value
The dot shift amount for
TRAY2 is set.
MPT / MN DOT SHIFT
**H mm
0H-FH
Correction
value
The dot shift amount for MPT/
MN is set.
Hatched portion: Default is shown
6.4.2.10 LED head serial number display
This self-diagnostic menu item is used to check whether the downloaded LED head data
matches the serial number of the actual LED head.
1. Enter the self-diagnostic mode (level 1), press the [2]
or
[8] key repeatedly ,and
press the [6] key when the "LED HEAD DATA" is displayed in the upper row of the
display area. (Pressing the [2] key increments the test item and pressing the [8] key
decrements the test item.)
2. When the [2] key or the [8] key is pressed, serial numbers of the K LED head data
are displayed in order.
3. Pressing the [4] key terminates the test. (Returns to the status of step 1.)
K ** ** ****
xxxxxxxxxxxxx
** ** ****
: Rev number
xxxxxxxxxxxxx
: serial number
6.4.2.11 NVRAM parameter setting
Do not use this menu item.
Содержание MB461MFP
Страница 1: ...MB461 MB471 MB491 MB491 MB491 LP MPS4200mb MPS4700mb Maintenance Manual 031314C ...
Страница 72: ...Oki Data CONFIDENTIAL 44871001TH Rev 6 3 21 3 MFP INSTALLATION Sample MB471 Sample MB491 ...
Страница 103: ...44871001TH Rev 6 4 25 Oki Data CONFIDENTIAL 4 REPLACEMENT OF PARTS 4 2 8 13 LCD assy 1 Remove the LCD assy ...
Страница 114: ...44871001TH Rev 6 4 36 Oki Data CONFIDENTIAL 4 REPLACEMENT OF PARTS ...
Страница 138: ...Oki Data CONFIDENTIAL 5 LUBRICATING POINT 5 1 Lubrication point 5 2 ...
Страница 261: ...Oki Data CONFIDENTIAL 44871001TH Rev 6 8 69 8 TROUBLESHOOTING PROCEDURES Figure 7 4 Fuser Assy Contact plate ...
Страница 281: ...Oki Data CONFIDENTIAL 10 APPENDIX 10 1 List of Initialized range 10 2 10 2 Maintenance Manual for Second Tray unit 10 9 ...