44871001TH Rev.6
4-35
Oki Data CONFIDENTIAL
4.REPLACEMENT OF PARTS
(8) Remove the screw (silver, L=8mm) to detach the Core .
(9) Remove four screws (silver) , and remove the Plate Base (PWU) with to slide
along to the arrow in figure.
⑪
⑫
⑬
⑩
(Reference)
The situation of the Mainbody
without the Plate Base (PWU).
⑩
⑪
⑫
⑫
⑬
(10) Remove two screws (Black) and the screw (Silver) , remove the Plate-Clutch-
MPT .
(11) Remove four screws (Silver) , remove the Plate-Gear .
(12) Remove the Gear-Reduction .
(13) Remove the E-ring(RE3-SK) , remove the Regist Clutch .
(14) Remove the E-ring(RE3-SK) , remove the Hopping Clutch .
Remove the Spring from the current Regist Clutch or the current Hopping
Clutch . This Spring can be used to the new Regist Clutch or the new
Hopping Clutch .
㉔
(15) Remove the MPT Clutch
and the Gear-MPT . (MB451/MB451w/MB471/
MB471w/MB491/MB491+/MB491+LP/ES4191 MFP/MPS4700mb/MPS4200mb)
(16) Installing is performed by the inverse procedure with removing.
Note!
1. Beware of not to touch the DC motor inattentively (Do not rotate motor).
Содержание MB461MFP
Страница 1: ...MB461 MB471 MB491 MB491 MB491 LP MPS4200mb MPS4700mb Maintenance Manual 031314C ...
Страница 72: ...Oki Data CONFIDENTIAL 44871001TH Rev 6 3 21 3 MFP INSTALLATION Sample MB471 Sample MB491 ...
Страница 103: ...44871001TH Rev 6 4 25 Oki Data CONFIDENTIAL 4 REPLACEMENT OF PARTS 4 2 8 13 LCD assy 1 Remove the LCD assy ...
Страница 114: ...44871001TH Rev 6 4 36 Oki Data CONFIDENTIAL 4 REPLACEMENT OF PARTS ...
Страница 138: ...Oki Data CONFIDENTIAL 5 LUBRICATING POINT 5 1 Lubrication point 5 2 ...
Страница 261: ...Oki Data CONFIDENTIAL 44871001TH Rev 6 8 69 8 TROUBLESHOOTING PROCEDURES Figure 7 4 Fuser Assy Contact plate ...
Страница 281: ...Oki Data CONFIDENTIAL 10 APPENDIX 10 1 List of Initialized range 10 2 10 2 Maintenance Manual for Second Tray unit 10 9 ...