Warning
Risk of Electric Shock
There is a risk of electric shock during replacement of the low voltage power supply.
Use insulating gloves or avoid direct contact with any conducting part of the power
supply, and caution should be exercised during replacement.
The capacitor may take one minute to complete discharge after the AC cord is
unplugged. Also, there is a possibility that the capacitor doesn’t discharge because
of a breakage of the PCB, etc., so remember the possibility of electric shock to
avoid electric shock.
4.2.7 Power Supply Unit
(1) Remove the Cover-Side-R. (Refer to 4.2.4)
(2) Disconnect all of the three cables from Power Supply Unit (Board)
②
.
(3) Remove the four screws (Silver)
①
. Remove the Power Supply Unit
(Board)
②
.
(4) Remove the Sheet-Insulation-LV
③
.
(5) Remove the screw
④
.
(6) Remove the two screws (Silver:8mm)
⑤
and the screw(M4)
⑥
, and
remove Power Supply Unit (AC-Inlet)
⑦
.
(7) Assembling is performed by the inverse procedure with removing.
(Note on removing / assembling)
1. Beware of not to touch the DC motor inattentively (Do not rotate motor).
2. Do not apply excessive pressure to the power switch.
4-10