3-23
3.1.8 EEPROM Initialization
The treatment for EEPROM Initialization at each phenomenon is displayed
as Diagram 3-1.
Diagram 3-1 EEPROM Initial Setting Range
No
Phenomenon
CU EEPROM Area
PU EEPROM Area
Factory
Default
Area
User
Menu
Area
OP
Menu
Area
Administrator
Menu/
System
Maintenance
Menu Area (*3)
F/W
Revision
Area
Engine Maintenance Menu Area
Brands
Area
Drum
Counter
Page
Counter
Toner
Dot
Counter
1 User Maintenance Menu
MENU RESET Operation
−
−
−
−
−
−
−
−
−
2 F/W Revision check error
at the time of a power on.
−
−
(*4)
−
−
−
−
−
3 CU EEPROM area mapping
Revision check error at the
time of a power on.
(*4)
−
−
−
−
−
−
4 Brands area check error at
the time of a power on. (*1)
(*4)
−
−
−
−
5 Engine Maintenance Menu
ENGINE RESET Operation
−
−
−
−
−
−
−
(*2)
(*5)
6 PU EEPROM area
mapping check error at the
time of a power on.
−
−
−
−
−
−
(*3)
7 FAC MAINTE MENU
EEPROM RESET Operation
−
(*4)
−
−
−
−
−
−
(*1) Destination Check is for the operation on the different product (destination) with the previously operated
product (destination). It is the reset relying on the recognition regarding the destination change by PJL
command and the operation at POWER ON of the new product EEPROM as an error.
(*2) It is reset to 0 limited by Page Count less than 500 pieces. (ENGINE RESET due to PJL Command is
not in this limitation.)
(*3) About DOT SHIFT setting menu, even it is also exist in System Maintenance Menu, but because
the setting value keeping area is allocated in PU EEPROM AREA, in the case of the item of System
Maintenance Menu initialized, DOT SHIFT setting is not initialized. By contraries, in the case of PU
EEPROM AREA initialized, DOT SHIFT setting is initialized.
(*4) DOT SHIFT setting should not be initialized.
(*5) Because of the support of Toner TAG, Toner Dot Counter is not reset.
3.1.7 Energy conservation mode setting
This printer is equipped with two types of energy conservation mode, MODE1
as "NORMAL MODE" and MODE2 as "ECO MODE."
When energy conservation mode is set to "ECO MODE," the printer prints at a
low speed at the beginning of cold start to reduce the period of time required
for warming up from the normal temperature.
At factory default, it is "ECO MODE" MODE2.
1. Setting method
(1) Switch on the power of printer.
(2) After "ON LINE" appears, open the Stacker Cover.
(3) Press [ON LINE] switch for 5 second.
Open the Top Cover by ONLINE and NODATA status, press [ON LINE]
switch for 5 second. The following setting information displays on LCD for
2 second. Then it returns to the original display automatically. The check
LED blinks.
•
In case of setting converted by MODE1 "NORMAL MODE" status, it
changes to MODE2 "ECO MODE".
ENGINE CONTROL
MODE2
*
•
In case of setting converted by MODE2 "ECO MODE" status, it
changes to MODE1 "NORMAL MODE".
ENGINE CONTROL
MODE1
*
3. ADJUSTMENT