6.  “

kg

” s dsplayed.  Ths s the Calbraton Weght Unt.  Press 

ON/OFF

-Yes to  

 

 

accept and move on to the next parameter.

 

7.  “

xxxx

” s dsplayed.  Ths s the Full Scale Capacty of the scale, where:   

 

      “1500” = 1.5kg, “3000” = 3kg, “6000” = 6kg, “15000” = 15kg.  Make    

             sure the dsplayed value matches the scale model capacty then press 

ON/ 

 

 

OFF-Yes

 to accept and move on to the next parameter.

 

8.  “

- - - - - -

” s dsplayed.  Make sure the pan s empty and stable at ths tme  

 

 

then press 

ON/OFF-Yes

.  The dsplay wll count down from 5 to 1 as the   

 

 

scale zero s regstered.

 

9.  “

xxxx

” s dsplayed.  Ths s the Calbraton Pont correspondng to 2/3 of  

 

 

the Full Scale Capacty value.  Place the ndcated calbraton weght on    

        

the center of the pan. Wth the scale stable, press 

ON/OFF-Yes.

  The dsplay  

 

 

wll count down from 5 to 1 as the scale regsters the calbraton weght.

 

10. 

“xxxx”

 s dsplayed.  Ths s the Calbraton Pont correspondng to the Full  

 

 

Scale Capacty value.  Place the ndcated calbraton weght on the center  

 

 

of the pan.  Wth the scale stable, press 

ON/OFF-Yes

.  The dsplay wll    

 

 

count down from 5 to 1 as the scale regsters the calbraton weght.

 

11.  “

SAVE

” s dsplayed when calbraton was regstered.  Remove the    

 

 

 

calbraton weght, then press 

ON/OFF-Yes

.  The scale wll dsplay a self-  

 

 

test then return to normal weghng mode.

Note

: At any tme durng the calbraton process, press 

CHECK-Back

 to revert to the 

prevous parameter, or long-press

 ON/OFF

 to turn off the scale and abort the process 

wthout savng any changes.

Содержание BW1.5

Страница 1: ...BW Series Compact Bench Scale B scula compacta de mesa de la Serie BW Balance de table compacte s rie BW Kompakte Tischwaage der BW Serie Bilancia da banco Compact serie BW...

Страница 2: ...ii...

Страница 3: ...nung Bassa tensione 89 336 EEC EN61326 1 A1 1998 A2 2001 Electromagnetic compatibility Compatibilidad electromagn tica Compatibilite lectromagnetique Elektromagnetische Vertr glichkeit Compatibilit el...

Страница 4: ...apa de la verificaci n inicial debe ser llevada a cabo por la organizaci n de servicio aprobada del represent ante autorizado dentro de la CE o por las autoridades nacionales de pesos y medidas La pri...

Страница 5: ...sprechenden Beh rden f r Ma e und Gewichte informieren Gli strumenti di pesa certificati sul luogo di fabbricazione recano sull etichetta della confezione uno dei marchi mostrati qui accanto e l adesi...

Страница 6: ...disponga de este producto de acuerdo con las normas locales en el punto de recolecci n especificado para equipos el ctricos y electr nicos Si tiene alguna pregunta s rvase consultar a la autoridad re...

Страница 7: ...lls bermittelt werden Vielen Dank f r Ihren Betrag zum Umweltschutz In base alla direttiva europea WEEE 2002 96 CE sui rifiuti di apparecchiature elettriche ed elettroniche Waste Electrical and Electr...

Страница 8: ...ion d enregistrement ISO 9001 Ohaus Corporation tats Unis d Am rique confir mant que le syst me de gestion de la qualit Ohaus tait conforme aux condi tions normalis es de l ISO 9001 Le 15 mai 2003 Oha...

Страница 9: ...2 Battery Power EN 4 2 6 Initial Calibration EN 4 3 OVERVIEW OF CONTROLS AND FUNCTIONS EN 5 4 OPERATIONS EN 6 4 1 Switching the Unit On and Off EN 6 4 2 Manual Tare EN 6 4 3 Zero Operation EN 6 4 4 Ch...

Страница 10: ...P65 dust and water jet protection 4 adjustable leveling feet with integrated front panel leveling indicator Bright red LED weight display 6 digit 7 segment 14 mm high characters 4 button control panel...

Страница 11: ...to ensure proper transport protection 2 3 Selecting the Location Operate the scale on a firm level surface Avoid locations with rapid temperature changes excessive air currents vibrations electromagn...

Страница 12: ...by the illuminated LED over the indi cator NOTES To maximize battery power the scale can be set up to enter Sleep mode only decimal points are displayed after 2 minutes of inactivity or auto matically...

Страница 13: ...xits to Save In CHECK Mode ends Over Under setup and exits to weighing mode Initiates CHECK Over Under setup In SETUP Mode Back reverts to the previous parameter In CHECK Mode shifts to the next digit...

Страница 14: ...ompares the weight of an item against a pre set Over Under range To activate Checkweighing Mode refer to user setup Section 5 2 Press CHECK to initiate entering Over Under parameters The value of the...

Страница 15: ...minutes of inactivity ON enables this function OFF disables this function S2 Scale enters sleep mode after 2 minutes of inactivity ON enables this function OFF disables this function S3 CHECK activat...

Страница 16: ...at the bottom of the scale then short the calibration pins a small slotted screwdriver may be used Note When accessing the bottom of the scale avoid placing the scale upside down on the pan or sub pla...

Страница 17: ...lue Place the indicated calibration weight on the center of the pan With the scale stable press ON OFF Yes The display will count down from 5 to 1 as the scale registers the calibration weight 10 xxxx...

Страница 18: ...scale may be sealed in the following manner Lead and Wire Seal Secure sealing plate with through hole screws Run the wire seal into the through holes then press the lead seal in place Sticker Seal Sec...

Страница 19: ...scale Inspect the scale regularly Ensure that the housing pan and sub platform are clean and free from foreign material Wipe the exterior components of the scale using a soft cloth dampened with water...

Страница 20: ...sub platform are unobstructed Scale does not display accurately Improper calibration Calibrate the scale using proper calibration weights nnnnnn displayed Overload condition Load on the pan exceeds sc...

Страница 21: ...BW SERIES COMPACT BENCH SCALE EN 13 9 TECHNICAL DATA 9 1 Drawings 230 mm 180 mm 230 mm 127 mm 310 mm...

Страница 22: ...tile mechanical keys ON OFF CHECK TARE ZERO Calibration Weight 2 3 and Full Scale Capacity Over Range Capacity Full Scale Capacity 9d Tare Range Full Capacity by Subtraction Zero Range Power on 10 Key...

Страница 23: ...ct has been damaged by accident or misuse exposed to radioactive or corrosive materials has foreign material penetrating to the inside of the product or as a result of service or modification by other...

Страница 24: ...rededor del mundo Avec des bureaux dans le monde entier Weltweite Gesh ftsstellen Con uffici in tutto il mondo www ohaus com P N 80251077 A Ohaus Corporation 2006 all rights reserved todos los derecho...

Отзывы: