BW SERIES COMPACT BENCH SCALE EN-7
• The LED ndcaton s complemented by an audble alert feature (Secton
5.2).
• Over-Under values are retaned when the unt s turned off.
• Over-Under values are not retaned when the weghng unt or resoluton
setup are changed.
5. SCALE SETTINGS
5.1 Accessing the User Setup Mode
Wth the scale off, press
ON/OFF
and
ZERO
smultaneously. Once the scale turns on,
release
ON/OFF
whle contnuously pressng
ZERO
untl
“SETUP”
s dsplayed. To
navgate n the User Setup Mode:
• Press
ON/OFF-Yes
to accept the dsplayed settng
• Press
TARE-N`o
to toggle through avalable settngs
• Press
ZERO-Exit
to end setup and proceed to “Save”
• Press
CHECK-Back
to revert to the prevous parameter
5.2 User Setup Parameters
Parameters
Description
Settings
S1
Scale automatcally turns off after 15
mnutes of nactvty.
ON - enables ths functon.
OFF
-dsables ths functon.
S2
Scale enters sleep mode after 2
mnutes of nactvty.
ON
- enables ths functon.
OFF -dsables ths functon.
S3
CHECK actvaton and Alert Range
0
- Check mode s off.
Scale beeps when dsplayed weght s:
1-...wthn the preset Over and Under values
2-...outsde the preset Over and Under range
3-...wthn the preset Over and Under values (Over-Under LED’s do not
lght wthn preset range)
4-...outsde the preset Over and Under range (Over-Under LED’s do not
lght wthn preset range)
5- Alarm s off (Over-Under LED’s do not lght wthn preset range)
6- Alarm s off
S4
Averagng Level
0, 1,
2
, 3 (most flterng, longer stablzaton tme)
4, 5, 6, 7 (corresponds to 0, 1, 2, 3 but wth slower dsplay update)
S5
Weghng Unt
kg
, g
S6
LED Brghtness Level
0
,1,2,3 (dmmest).
S7
Dsplay Type
OFF
- dsplays weght contnuously.
ON - dsplays frst stable weght.
S8
Resoluton
OFF
- 3000 scale dvsons
ON - 6000/7500 scale dvsons
Note
: Bold settngs are defaults.