Octalarm is a registered trademark  

From Adesys bv, Wateringen, NL 

 

Edition 16-08-2002 

OCTALARM

 ®

-T2 

OCTALARM

 ®

-T4 

OCTALARM

 ®

-T8 

OCTALARM

 ®

-T16 

 

 

Содержание T16

Страница 1: ...Octalarm is a registered trademark From Adesys bv Wateringen NL Edition 16 08 2002 OCTALARM T2 OCTALARM T4 OCTALARM T8 OCTALARM T16 ...

Страница 2: ...election keys 12 6 3 Device malfunction indicators 12 6 4 Reset key 13 6 5 Test key 13 6 6 Buzzer key 13 6 7 Telephone dialler key 13 6 8 Display and cursor keys 13 6 9 Prog key 14 6 10 Esc key 14 7 SET CALL NUMBERS 15 7 1 Report to a telephone 15 7 2 Report to a pager 16 7 2 1 Characteristics of a tone only pager 16 7 2 2 Characteristics of an alpha numerical pager 16 7 3 Report to a mobile telep...

Страница 3: ...ns 34 17 1 1 Programming using the operation panel 34 17 1 2 Programming using the PC 34 17 1 3 Programming using a telephone line 35 17 1 3 1 Analogue or ISDN model 35 17 1 3 2 GSM model 35 18 INSTALLATION PROGRAMS 36 18 1 Prog 10 set display contrast 36 18 2 Prog 11 show version number 36 18 3 Prog 21 set alarm inputs 36 18 4 Prog 23 set alarm on display 37 18 5 Prog 31 set alarm buzzer 37 18 6 ...

Страница 4: ... in emergency power supply mains supply guard guard of battery performance telephone line test flashlight output remote control output night time mode data log Sensornet connection only for versions T4 T8 and T16 access protection extensive test facilities RS 232 connection permanent memory for all settings and report texts Operation and configuration are menu driven They take place using the cont...

Страница 5: ...ctalarm s model number by pressing the test button after having switched it on The display will show the message OCTALARMTEST followed by the model number OT2 OT4 OT8 or OT16 followed by S model with voice messages instead of tone code messages I model for the ISDN network G model for the mobile GSM network or a combination of the above After connecting it to a wall socket the Octalarm switches on...

Страница 6: ...condition that the guarantee card is completed and returned upon taking into operation The guarantee claim expires when the malfunction is caused by gross negligence or by incompetent installation the device has been repaired and or altered without permission of ADESYS the serial number on the device is removed or damaged ADESYS rejects any liability for consequential damage caused by incompetent ...

Страница 7: ...al telephone number pager number number of reporting service select the same or the succeeding number after the set delay time already 15 failures end occupied or not answered tone code or voice message report to pager report to reporting service reset by call back set wait for call back called back in time report correctly reset end no yes yes no no no no yes yes yes ...

Страница 8: ...ntil the reset procedure is properly accomplished After 15 unsuccessful attempts the Octalarm will reset itself It is possible to set a specific dialling order for each alarm channel This alteration has to be carried out in the installation program See paragraph 18 7 Prog 42 set dial sequence Alterations of dialling order have to be carried out carefully because it might happen that an alarm will ...

Страница 9: ...oosing If required all codes can be altered using the installation program 55 4 3 3 Report to mobile telephone The Octalarm can report to mobile telephones in two different ways by means of a pre set tone code or by a self recorded voice message version S as with a normal telephone by using the Short Message Service SMS whereby the device s display is used as a pager The report messages used for t...

Страница 10: ...sed on in groups as much as possible With telephone reports more than one alarm is heard at the same time and in case of a report to a pager or a reporting service the report codes are passed on immediately after each other In this way the alarms are reported quickly and they can be reset simultaneously 4 5 2 Reporting channels with a deviant dialler A selection from the call numbers entered has b...

Страница 11: ...lt Only disable at the moment the reset key is pressed The default start and stop conditions can be modified using the installation program See paragraph 18 5 Prog 31 set alarm buzzer The volume of the internal buzzer can be adjusted from 0 up to 4 factory default 2 When connecting the external buzzer optional accessory supplied by ADESYS its volume can be adjusted to three levels 5 2 Flashlight T...

Страница 12: ...ission can be switched off for each alarm channel at Octalarm T16 per two alarm channels The green indicator in the key lights up in case the passing of the report is enabled To avoid the transmission of the message being interrupted accidentally e g while cleaning the key has to be kept depressed when turning off When an alarm channel is switched off green LED off an incoming alarm on the relevan...

Страница 13: ...ase the telephone dialler is switched on To avoid switching off the telephone report accidentally e g while cleaning the key has to be kept depressed when turning off In case the telephone dialler is switched off LED off an alarm will not be reported by telephone Calling up the Octalarm in order to receive the alarm status by telephone will however remain possible 6 8 Display and cursor keys The d...

Страница 14: ...he set up program during configuration by using the esc key will restore all previous settings In case this key is pressed prolonged five seconds the Octalarm will switch over to the installation program The text Prog10SETDISPLAYCONTRAST will appear on the display Press the esc key to leave this program The settings in this program require understanding of technical matters and are only intended f...

Страница 15: ... 4 Report to reporting services A number can be erased completely by selecting NOTDEFINED Confirm each new or altered setting by pressing the Prog key repeatedly until the message SETTINGSSTOREDappears on the display Quitting the set up program during configuration by using the esc key will restore all previous settings After erasing the only call number set for a particular alarm it is no longer ...

Страница 16: ...stions such as pagernumber this question will only appear when using a pager with a general paging service extension number followed by a unique pager number pincode this question will appear for pagers using some sub address These pagers do not involve any subscription expenses because many pagers are placed on one single subscription Separation takes place by the sub address in the report code I...

Страница 17: ...wait for an undefined dialling tone used in combination with the C and D keys to insert or delete digits at the position of the cursor BConfirm the entered number using the Prog key BIn case of an SMS report the Octalarm will ask for the extension number BSelect the desired reset procedure see paragraph 7 5 Set reset procedure 7 4 Report to a reporting service Select the kind of reporting service ...

Страница 18: ...ween a failed report attempt and a new dialling attempt and confirm using the Prog key The following text will appear on the display SETTINGS STORED 7 5 3 Reset by calling back BSelect this option and confirm using the Prog key BEnter the time in which the Octalarm has to be called back and confirm using the Prog key BIf necessary enter the reset code to be applied and confirm using the Prog key T...

Страница 19: ...pens to call the Octalarm within the set delay time the Octalarm is reset accidentally Therefore the use of a reset code is strongly recommended 8 2 Reset using a reset code In case the call number is provided with a reset code after the alarm report the Octalarm will send short waiting beeps with extended pauses in between indicating the reset code to be entered now Enter the reset code using the...

Страница 20: ...f necessary alter the number of signals after which the Octalarm has to answer the call or completely switch off this function using the installation program 10 SWITCHING THE RELAY OUTPUT BY TELEPHONE The Octalarm is equipped with a relay control output A connected relay can be controlled at a distance using a telephone for example to reset an alarm device temporarily release an entrance door swit...

Страница 21: ... time mode is activated automatically the moment the burglar alarm is switched on for instance when leaving the location The reports can be carried out as follows Reports during daytime The acoustic alarm sounds instantly after detecting an alarm The telephone report only starts after 5 minutes allowing a prior reset of the Octalarm The acoustic alarm does not stop until the device has been reset ...

Страница 22: ...iod that can be backed up with the built in battery strongly depends on the operation mode and the external signal devices In general a new battery obtains a back up supply of approximately 15 hours in standby mode approximately 10 hours in case of a continuous acoustic alarm through the built in buzzer approximately 3 5 hours in case of a continuous acoustic alarm through the built in buzzer and ...

Страница 23: ...omatically 13 2 Telephone report test Press the test key followed within 5 seconds by the selection key of the alarm channel to be tested The set report procedure for the relevant channel will be passed through completely With the model for analogue or ISDN connections the built in speaker produces all signals on the telephone line making it possible to trace possible set up errors of telephone nu...

Страница 24: ...sage has been sent to a non existent ISDN call number Check the call number installed ISDN S BUS DEFECTIVE The Octalarm has detected that there is no power on the ISDN line i e the S box Check the ISDN line and the ISDN connection cables ISDN NETWORK ERROR XX There is a failure in the service provider s ISDN network Wait for a while to see whether the failure continues If it does contact your serv...

Страница 25: ...ation Detach the hindmost breakaway partition for leading the connection cables into the back After connection fix the connection cables to the little bridges on the backplane avoiding tensile strain Mounting onto a wall The backplane of the Octalarm has two notches for mounting it onto a wall Install the Octalarm as follows BScrew the Octalarm against the wall using the middle hole only visible f...

Страница 26: ... 3 Connection of inputs All inputs have to be activated by potential free contacts 16 3 1 Alarm inputs Both normally open and normally closed contacts can be applied For the connection it is possible to choose between a direct connection to the Octalarm or a connection through Sensornet only possible for Octalarm T4 and T8 Using a Sensornet connection can save on wiring because all inputs are conn...

Страница 27: ...able Connection block number With polarity With Octalarm T4 activates With Octalarm T8 activates With Octalarm T16 activates 1 alarm 1 alarm 1 alarm 9 2 alarm 2 alarm 2 alarm 10 3 alarm 3 alarm 3 alarm 11 4 alarm 4 alarm 4 alarm 12 1 alarm 1 alarm 5 alarm 13 2 alarm 2 alarm 6 alarm 14 3 alarm 3 alarm 7 alarm 15 4 alarm 4 alarm 8 alarm 16 The Octalarm T4 and T8 are allowed to see each terminal bloc...

Страница 28: ...st place indicating the alarm still applies Switching off only takes place when the alarm expires or when the selection key concerned is switched off 16 4 2 External buzzer outputs Outputs for connecting additional acoustic signal devices or for controlling existing alarm systems There are two connection options Output NO Normally Open will be active in case of an alarm It can be used for the dire...

Страница 29: ...circuit in the telephone network owing to the A A and B B reconnection when not active If so set up an additional RJ 11 connection box with only the two centre pins connected or else use a 2 core connection cable rather than the standard 4 core model supplied Avoid connecting the Octalarm behind a telephone switchboard In the case of a network failure the connections of telephone switchboards ofte...

Страница 30: ...ccording to the telecommunication guidelines the Octalarm also has a disconnection relay with which the peripherals can be fully disconnected if necessary It is therefore advisable to reconnect all other ISDN equipment to the Octalarm s TEL connection The recommended connection scheme is as follows NT1 S bus Cable disconnection NT1 Octalarm T S box on on 1 2 on off NT1 overige rand apparatuur S bu...

Страница 31: ... NT1 overige rand apparatuur S bus S bus 2x 100Ω overige rand apparatuur Cable disconnection NT1 Octalarm T S box off on 1 2 on on Always connect the Octalarm to the NT1 s S box avoid connecting it to an S box behind a switchboard because The internal S box of the switchboard will often stop working in the case of a network failure preventing the Octalarm from sending a telephonic warning The inte...

Страница 32: ...ogue lines 16 6 Placing and connecting the GSM antenna only for Octalarm GSM model 16 6 1 Internal antenna Connect the two antenna plugs in the connection compartment to one another Connect the antenna provided to the connector on the outside of the cover Always place the antenna upright for maximum signal strength 16 6 2 External antenna Place the external GSM antenna using the instructions in th...

Страница 33: ...tocols some of which are not yet supported by all network providers See the GSM enclosure provided for an up to date list 16 8 Connecting the COM port The COM port is designed in accordance with the V 24 RS 232 standard and provides the following signals PIN nr Name In Out Description 2 TXD in Transmit Data 3 RXD out Receive Data 4 RTS in Request To Send 5 CTS out Clear To Send 6 DSR out Data Set ...

Страница 34: ...ars on the display You are now in the installation program BSelect the number of the program that you want to modify or check the settings by using the E and F keys Press the Prog key again in order to start the program In case a blinking setting or cursor appears a selection can be made using the E and F keys Use the cursor keys C and D to move the cursor around Confirm each new setting by pressi...

Страница 35: ... available beforehand in prog 61 setting access code Remote programming is not possible without an access code If the Octalarm has been set so that the alarm status is first transmitted by telephone it will take longer before the modem connects Take this into account when setting up the transmitting modem It may be necessary to increase the waiting time for the carrier Most modems use the command ...

Страница 36: ...for Octalarm T4 and T8 See paragraph 16 3 1 2 Connection through Sensornet ALARMDELAY 00 00 MIN SEC Set the desired alarm delay time The alarm will only be issued after the activation of the alarm exceeds this delay time MEMORYFUNCTIONONALARM OFF ON Define whether the report has to stop or whether it must be finished in case the alarm expires OFF both the local and telephone report are interrupted...

Страница 37: ...ing 15 failing dialling attempts The alarm buzzer will however sound immediately in case the telephone dialler key is switched off AFTERDELAY the alarm buzzer only sounds after the set delay time has elapsed With this option the following additional question appears DELAYTIME 01 MIN Set the desired delay time here from 1 to 99 min ALARMBUZZEROFF AFTERTEL RESET BYRESETKEY AFTERDELAY Set the stop co...

Страница 38: ...switched off AUTOANSWERAFTER 05RINGS Here you can enter the number of rings 1 through 19 the Octalarm has to wait for before answering an incoming call in order to pass on the alarm status DIALMODE PULSE TONE DTMF Here you can define whether the dialling of call numbers has to be done using pulse or tone dialling WAIT FIRSTDIALLINGTONE YES NO Set this option to no only if it turns out that the Oct...

Страница 39: ... the alarm channels using tone code or speech model S In case the selected option is offand a telephone report is being acknowledged by a call back only if this is set with the relevant telephone number the Octalarm answers after 2 rings In case the selected option is on retrieving the alarm status is always possible even when the telephone dialler key is switched off ANSWERAFTER 05 CALLSIGNALS Us...

Страница 40: ...rm will nevertheless answer If this option is set to on it is always possible to access the alarm status even if the telephone dialler button has been switched off SMScentralnumber To send SMS messages Octalarm needs the so called SMS central number This number is provided by the network operator or service provider when you take out your subscription Enter that number here SetGSMPINcodeyes no If ...

Страница 41: ... The reporting stops after 15 unsuccessful report attempts Creating reporting groups is possible as well The call numbers belonging to one group are entered immediately after one another Groups of call numbers are divided by a sign In an alarm situation a report will be sent at first to the first group After one of the call numbers resets the report by telephone a new report cycle to the next repo...

Страница 42: ... can lead to an alteration of the order in which simultaneously occurring alarms are reported See for the regarding effects paragraph 4 5 More than one alarm simultaneously AUTOMATICREPEAT YES NO Define whether an automatic repeat of a telephone alarm is desired NO the telephone report will be carried out only once following the dialling order set with the reporting channel YES the telephone repor...

Страница 43: ...arm 14 alarm 15 alarm 16 mains failure 4 9 or 90 OT16 mains failure battery empty 4 10 or 91 OT16 battery empty failure 18 8 1 Set report codes tone only pager Select the option SETREPORTCODESTONE ONLYPAGER After the Prog key is pressed the following appears ALARMCHANNEL1 1 Here enter the code 1 through 8 to appear on the pager in case alarm channel 1 is activated When using the report codes 5 to ...

Страница 44: ...al message for every connected alarm channel and for the alarms mains failure and battery empty as well With the Octalarm T16 also speak in the opening message This message will be sent prior to the message set for the alarm channel in question The opening message can be used for such things as sending a location name A spoken message will be shown by the telephone if the alarm in question is sent...

Страница 45: ...e after the access code is entered ACCESSCODE 0000 Enter the 4 digit access code here Programming from a distance without the use of an access code is never possible 18 11 Prog 71 set night time mode Here you can define in what way the alarm report has to be carried out when the Octalarm functions in night time mode AL BUZZERNIGHT OFF ON Define whether the use of the internal and external alarm bu...

Страница 46: ... the chosen volume during programming NIGHTTODAY ALARMBUZZERON ALARMBUZZEROFF Here you can define whether the buzzer key has to be switched on or off when the night time mode is disabled DIALLERNIGHT OFF ON Define whether a telephone report at night is desirable If so the following question appears DIALLERDELAY 00MIN Here you can enter the desired delay time from 1 to 99 min NIGHTTODAY DIALLERON D...

Страница 47: ... A CHANGED The call number A shown is changed on time xxx xx XXX XX PROGzz CHANGED Program zz is changed on time xxx xx In case this regards Prog 42 dial sequence the alarm channel of which the order has been changed is indicated as well XXX XX SELECTION 1 567 TZ At time xxx xx the position of the selection keys has been changed In this example the alarm selection keys 1 5 6 7 and the telephone di...

Страница 48: ...Octalarm is reset manually or alarm 1 has expired 18 14 Prog 98 choose language Choose between the languages Dutch German French or English From now on all messages except self defined will appear on display in the chosen language 18 15 Prog 99 clear all settings By erasing all the settings the Octalarm will function according to the factory defaults again Due to protection the question will be as...

Страница 49: ...10 to 15Vdc nominal 12Vdc short circuit protected RS 232 port 25 pole female sub D connections in accordance with standard DCE at which connected signal pin input output RXD 2 input TXD 3 output RTS 4 input CTS 5 output DSR 6 output GND 7 CD 8 output DTR 20 input RI 22 output Baud rate 19 200 baud Power supply 205 245Vac 50 60Hz Power consumption 4 9 Watt Emergency power supply maintenance free le...

Страница 50: ...arm T2 T4 T8 T16 Settings summary Call numbers report to reset telephone tone only pager alpha numerical pager mobile voice tone mobile SMS reporting service number by call back during report by report service reset code delay time A B C D E F G H I J ...

Страница 51: ...pen NO closed NC direct via sensornet alarm delay with memory reset if succesful input 1 min input 2 min input 3 min input 4 min input 5 min input 6 min input 7 min input 8 min open NO closed NC alarm delay with memory reset if succesful input 9 min input 10 min input 11 min input 12 min input 13 min input 14 min input 15 min input 16 min batt empty min mains failure min ...

Страница 52: ... alarm buzzer alarm buzzer on direct at alarm if dialling fails after delay min volume internal buzzer alarm buzzer off after tel reset by reset key after delay min Prog 41 set dialler analogue model report delay min auto answer off on after rings dial mode tone dtmf pulse dtmf wait for first dialling tone yes no telephone line test on off Prog 41 set dialler ISDN model report delay min MSN number...

Страница 53: ...ntral number PIN code PUK code unblocking Prog 42 set dial sequence report repeat all numbers off selective to automatic time hrs min input 1 input 2 input 3 input 4 input 5 input 6 input 7 input 8 report repeat all numbers off selective to automatic time hrs min input 9 10 input 11 12 input 13 14 input 15 16 battery empty mains failure ...

Страница 54: ...nnel 6 channel 7 channel 8 channel 9 channel 10 channel 11 channel 12 channel 13 channel 14 channel 15 channel 16 mains failure batt empty defect main message Prog 59 record voice messages recorded text channel 1 channel 2 channel 3 channel 4 channel 5 channel 6 channel 7 channel 8 recorded text channel 10 channel 11 channel 12 channel 13 channel 14 channel 15 channel 16 mains failure batt empty d...

Страница 55: ...t time mode alarm buzzer night off on alarm buzzer night on direct at alarm If dialling fails after delay min alarm buzzer night off after tel reset by reset key after delay min volume internal buzzer night to day alarm buzzer on alarm buzzer off dialling night off on report delay at night min night to day dialler off dialler on keys blocked at night no yes Prog 95 sensor test Prog 97 read data lo...

Страница 56: ...Settings summary Adesys bv Wateringen NL 56 Octalarm T2 T4 T8 T16 Notes ...