Edit parameters
The unit is supplied with a pre-set of parameters in accordance with the machine configuration.
For normal use, reconfiguration is not necessary during installation operations.
Parameter change is only possible with the system energised in STOP mode and with the
parameter access option enabled.
To modify the parameters:
●
press the MENU access button (P4);
●
press the navigation buttons (P4.2) and (P4.3) and select the desired function (see parameter diagram);
●
press the confirmation button (P4.4);
●
press the navigation buttons (pg-) and (pg+) and select the desired menu item;
●
press the change button (mod);
●
press the option buttons (sel-) and (sel+) and select the desired value;
●
press the confirmation button (ok).
Changing parameters may require updates of derived parameters. In the example, changing
the B2 current level requires updating the relative range (ex. from 3.3-3.5A to 3.5-3.7A)