OceanDMX RC
.
2021 INSTALL & OPERATION MANUAL
12
2.5 INSTALLATION E6/E7
The DMX standard recommends a maximum of 32 devices to be connected in one chain. If installation
requires more lights than this, please contact OceanLED for advice.
1. Connect the DMX control cable to the control input of the first Explore E6/7 light. Then connect a control link
cable to the next, and so on up to the last light in the chain.
The power supply to the DMX Receiver should be fused with 500mA inline fuse (not supplied).
2. Fit the supplied terminator to the output of the last E6/7 light. See the following example of the connections:
LAST LIGHT TO BE
TERMINATED
WITH TERMINATOR
Remote
Colour
DMX Receiver
TERMINATOR
Depending on the current rating requirements of the installation it is highly
recommended to install a suitably rated relay with remote switch to control
power (not supplied). This will reduce potential issues with voltage drops in the
system.
FU
SE
POWER SUPPLY
12/24V DC
SWITCH
/RELAY
FUSE/
BREAKER
FUSE
FUSE
FUSE
FUSE
Control Link
Cable
Control Link
Cable
Control Link
Cable
Remote
Dual-Colour
OR
DMX
Control Cable - 5m
(supplied)
POWER CABLING
(not supplied)