10
2.
Locate DIP switch packages SW1 (switches 1 .. 8) and SW2 (switches 1, 2).
3.
Set the device address DIP switches 1 through 8 using the following table. Each device on the RS-485 network must have
a different address. You can configure up to 256 devices (address 0 .. 255) on the RS-485 network. The switch package
indicates which position is ON and which is OFF.
Table 1. DIP address switch settings
Dome Address
SW1 (address) switch number
1
2
3
4
5
6
7
8
0
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
1
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
2
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
3
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
4
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
5
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
6
OFF
ON
ON
OFF
OFF
OFF
OFF
OFF
7
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
8
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
9
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
…
…
…
…
…
…
…
…
…
255
ON
ON
ON
ON
ON
ON
ON
ON
4.
Set the network baud rate DIP switches 1 and 2 using the following table. Each device on the RS-485 network must use the
same baud rate. By default, the baud rate is set to 2400 baud (1
g
OFF, 2
g
OFF).
Baud rate
SW2 switches
1
2
2400
OFF
OFF
4800
ON
OFF
9600
OFF
ON
19200
ON
ON
5.
Reinstall the SWITCH cover plate.
SECTION 2: INSTALLATION
Содержание BLK-PTZ36XIR
Страница 8: ...viii...
Страница 16: ...8 SECTION 1 INTRODUCTION BLK PTZCM Corner Mount PTZ Bracket 7 64 6 96 G 1 5 16 52...