- EN -
Questions, problems, missing parts?
Before returning to your retailer, call us at 1
-866-627-
3435, 8 a.m.
-
6 p.m., EST, Monday
-
Friday, or email
us at customercare@oase-
livingwater.com. Or visit our website at www.oase
-
livingwater.com
35
System message
Functions that are still
available
Possible cause
Remedy
Resetting the system
message
Er44
Motor blocked
(The control system attempted
to start up the motor three
times -
5 times per attempt)
None
Filter drum rotating sluggishly or jammed
•
Clean edge of the drum/drum seal and grease edge of the
drum Only use original OASE grease (order number 27872).
•
Ensure that the rollers move smoothly
•
Remove larger particles (e.g. snails, stones) from the sprocket
Press
key for 5
s
The lips of the drum seal were squeezed
when the drum was installed.
Disassemble the drum and ensure that the drum seal is
positioned correctly during re
-assembly
The drum load is distributed unevenly
Align the container horizontally
Er55
More than 960 cleaning cycles
in 48 hours
•
Manual cleaning
•
Automatic mode
•
Time-
dependent cleaning
Temporary heavy soiling
•
Start-
up phase of the filter system (e.g.
during the first start-
up)
•
Fish are spawning
Wait until the soiling decreases
•
This operating status is atypical. Avoid long
-term
operation in
this state.
•
Press
key for 5
s
•
Automatic if the number of
cleaning procedures drops
below 960.
Pond heavily soiled
•
Clean the pond
•
Reduce the amount of soiling
•
Install the filter pump in an elevated position.
Screen elements
heavily soiled
Clean the screen elements, descale (
→
Replacing screen
element)
Insufficient cleaning effect due to soiled
nozzle
•
Clean nozzle
Water level in the system too high:
•
Outlet pipes soiled
•
Clean outlet pipes
•
Outlet
opening too small
•
Enlarge outlet opening
•
Max. flow rate exceeded
•
Reduce flow rate
•
A large amount of dirt has entered the
filter system, water is flowing over
(instead of through) the foam filters.
•
Clean foam filters
Er66
Switch element for
rinsing
pump in the control system
overheated
None
Control system is exposed to excessive
heat (sun, ambient temperature)
Protect the control system from heat
Automatic when cooled down
Er88
The filter pump is not supplying
any water or insufficient water.
•
Manual cleaning
•
Automatic mode
•
Time-
dependent cleaning
Pump status detection incorrectly set
Set the pump status detection. (→
Automatic after elimination of
the cause
The filter pump is switched off.
Switch on the filter pump.
The impeller unit of the filter pump is
blocked.
Clean the filter pump.
Содержание Profi Clear Premium Compact L US
Страница 1: ...Pro Clear Premium Compact L US...
Страница 2: ...2 A ProfiClear0239...
Страница 3: ...3 B ProfiClear0243...
Страница 4: ...4 C ProfiClear0279 D ProfiClear0164...
Страница 5: ...5 E ProfiClear0129 F ProfiClear0130...
Страница 6: ...6 G ProfiClear0244 H ProfiClear0245 I ProfiClear0169...
Страница 7: ...7 J ProfiClear0240 K ProfiClear0280...
Страница 8: ...8 L EGC0009 M EGC0003 N ProfiClear0134...
Страница 9: ...9 O P PrifiClear0135 Q ProfiClear0041...
Страница 10: ...10 R ProfiClear0137 S ProfiClear0138...
Страница 11: ...11 T U ProfiClear0140 ProfiClear0141 V ProfiClear0139...
Страница 110: ...110 Proficlear0251 Proficlear0252...
Страница 112: ...112 Proficlear0254 Proficlear0255 Proficlear0256...
Страница 114: ...114 Proficlear0259...
Страница 116: ...76481 01 20...