5.1
Order of starting up steps
How to proceed:
C
1.
Close the slide valve for the dirt outlet at the bottom of the container.
2.
Check that the entire filter system (pipes and hoses) is complete.
3.
Remove the container cover.
–
The filter drum is stopped for safety reasons if the filter cover is lifted and
Er11
is indicated in the
display of the control system.
Moving bed filter chamber
The Moving Bed filter chamber contains three 5.3 gal sacks (20
l) of Hel-X 13 biomedia (15.9 gal (60 l)).
Optionally, 21.1
gal (80
l) can be used instead (supplementary kit, order no.: 43383).
4.
Tip the Hel
-
X biomedia from the bags into the moving bed filter chamber.
– Ensure that the Hel-
X biomedia can move around freely in the container.
–
It can take several weeks for the Hel
-
X biomedia to become completely colonised.
Uncolonised
Hex
-X biomedia tend to float more.
T I P
When using the supplementary kit, add the biomedia gradually. Recommendation: max.
1.3 gal (5 l)
per
week.
Filter drum
5.
Manually turn the filter drum for one whole rotation to ensure unobstructed movement.
6.
Fill the filter with water until the rinsing pump is submerged (dry run protection of the rinsing pump).
7.
Fit the container cover.
Switching on the control system and additional units, checking the pipes
8.
Switch on the control system and perform any necessary adjustments. (→ Operation
9.
Switch on the filter pump and
UVC
clarifier (if applicable).
–
Ensure that the water is returned to the pond via the return pipe.
10.
Check all pipes, hoses and their connections for leaks.
–
Expansion seals may leak initially until they have fully expanded on contact with water.
11.
Adjust the level detection device, if necessary. (→ Setting the level detection device
T I P
It takes approx. 3 to 4 weeks before the micro
-
organisms in new filters are fully established. During this
time -
or at a water temperature of <50
°F (<10
°C) –
the filter may overflow. In this case the filter does
not need to be cleaned.
►
When using filter starters, medicines or pond water treatments, leave the UVC pre
-
clarifier switched
off for at least 36
hours so as not to impair their efficacy.
Содержание Profi Clear Premium Compact L US
Страница 1: ...Pro Clear Premium Compact L US...
Страница 2: ...2 A ProfiClear0239...
Страница 3: ...3 B ProfiClear0243...
Страница 4: ...4 C ProfiClear0279 D ProfiClear0164...
Страница 5: ...5 E ProfiClear0129 F ProfiClear0130...
Страница 6: ...6 G ProfiClear0244 H ProfiClear0245 I ProfiClear0169...
Страница 7: ...7 J ProfiClear0240 K ProfiClear0280...
Страница 8: ...8 L EGC0009 M EGC0003 N ProfiClear0134...
Страница 9: ...9 O P PrifiClear0135 Q ProfiClear0041...
Страница 10: ...10 R ProfiClear0137 S ProfiClear0138...
Страница 11: ...11 T U ProfiClear0140 ProfiClear0141 V ProfiClear0139...
Страница 110: ...110 Proficlear0251 Proficlear0252...
Страница 112: ...112 Proficlear0254 Proficlear0255 Proficlear0256...
Страница 114: ...114 Proficlear0259...
Страница 116: ...76481 01 20...