- EN -
38
8
Maintenance and cleaning
W A R N I N G
Possible death or severe injury from hazardous electrical voltage!
►
Prior to reaching into the water, isolate (switch off and disconnect) all units/devices used in the water.
►
Isolate the device (disconnect from the power supply) before carrying out any work on it.
C A U T I O N
Risk of injury due to sharp
-
edged components.
►
Proceed with caution during any work on the filter container to prevent injuries caused by sharp
-edged
components.
8.1
Cleaning the device
►
Do not use aggressive cleaning agents or chemical solutions as they could attack the housing or
impair the function of the unit.
►
Recommended cleaning agent for removing stubborn limescale deposits:
–
Pump cleaning agent PumpClean
from OASE.
– Vinegar- and chlorine-free household cleaning agent.
►
After cleanin
g, thoroughly rinse all parts in clean water.
8.2
Regular tasks
The filter system is self-
cleaning. Carry out the following work regularly to ensure the optimum cleaning
capacity of the filter system.
Regular checks
►
Check the display of the control system for
any system messages.
(→
►
Check the area in front of the separating plate and the inside of the filter drum for excessive soiling
(e.g. string algae). To
do this, remove a screen element. (→ Removing/fitting a screen element
Removing accumulated dirt
Dirt that cannot be collected by the filter drum, sinks to the bottom and has to be removed.
►
Open the slide valve for the dirt drain (at the bottom of the container) for 10 seconds once a month.
►
Remove accumulated dirt in front of the filter drum.
►
Remove string algae from the dirt channel.
►
Remove accumulated dirt from
the level detection device.
8.3
Cleaning the entire filter system
►
The entire filter system only needs to be taken out of operation for cleaning and maintenance if it is
extremely soiled.
►
Do not use any chemical cleaning agents as they would kill the filter b
acteria.
How to proceed:
1.
Switch off all filter pumps.
2.
Switch off all other electrical units of the filter system (e.g. UVC clarifier).
3.
Open the slide valve for the dirt outlet at the bottom of the container and dispose of the soiled water
in a permissible way.
4. Carry out cleaning measures.
– Rinse the Hel-X bio-
elements in the container with running water.
5.
Close the slide valve (dirt outlet).
6.
Start up the filter system again. (→
Содержание Profi Clear Premium Compact L US
Страница 1: ...Pro Clear Premium Compact L US...
Страница 2: ...2 A ProfiClear0239...
Страница 3: ...3 B ProfiClear0243...
Страница 4: ...4 C ProfiClear0279 D ProfiClear0164...
Страница 5: ...5 E ProfiClear0129 F ProfiClear0130...
Страница 6: ...6 G ProfiClear0244 H ProfiClear0245 I ProfiClear0169...
Страница 7: ...7 J ProfiClear0240 K ProfiClear0280...
Страница 8: ...8 L EGC0009 M EGC0003 N ProfiClear0134...
Страница 9: ...9 O P PrifiClear0135 Q ProfiClear0041...
Страница 10: ...10 R ProfiClear0137 S ProfiClear0138...
Страница 11: ...11 T U ProfiClear0140 ProfiClear0141 V ProfiClear0139...
Страница 110: ...110 Proficlear0251 Proficlear0252...
Страница 112: ...112 Proficlear0254 Proficlear0255 Proficlear0256...
Страница 114: ...114 Proficlear0259...
Страница 116: ...76481 01 20...