- EN -
34
6.8
System messages
The 4-
digit system message is indicated in the display by two groups of two digits in succession.
System message
Functions that are still
available
Possible cause
Remedy
Resetting the system
message
Er11
Container cover raised
•
Manual cleaning (only
nozzles, filter drum not
rotating)
Container cover raised
Refit the container cover
Automatic when the container
cover is fitted.
Container cover
incorrectly fitted
Turn the container cover around so that the magnets in the
container cover are located over the signal box
Signal box not connected
Connect the signal box to the control system
Er22
Water temperature >53.6
°F
(12 °C) AND the last automatic
cleaning process was carried
out more than 24 hours ago
•
Manual cleaning
•
Automatic mode
•
Time-
dependent cleaning
Screen elements leaking
Check screen elements, replace if necessary
•
Press
key for 5
s
•
Automatic as soon as the
level detection device is
triggered
Drum seal leaking
Check the drum seal
Level detection device stuck or defective
Clean the level detection device to ensure that the mechanics
operate freely, replace if necessary.
Level detection device set incorrectly
Adjusting the level detection device
•
Manual cleaning
•
Automatic mode
24 hour check mode is active and time
-
dependent cleaning is deactivated.
Time-
dependent cleaning is automatically activated by floats
after check mode.
Er33
20 cleaning cycles in
succession
•
Manual cleaning
•
Time-
dependent cleaning
Level detection device stuck or defective
Clean the level detection device to ensure that the mechanics
operate freely, replace if necessary.
Press
key for 5
s
Screen
elements heavily soiled
Clean/descale the screen elements (→ Removing/fitting a screen
Rinsing pump not operating
•
Clean the bottom of the container, clean the rinsing pump
•
Check the pump connection
Rinsing nozzle clogged
Clean the rinsing nozzle
Filter drum not rotating
•
Check the motor connection
•
Check the rotating movement of the filter drum.
Tip: Mark the filter drum and check on the basis of the
markings if the drum rotates.
Level detection device set too low
Adjusting the level detection device
Water level in the system too high:
•
Outlet pipes soiled
•
Clean outlet pipes
•
Outlet opening too small
•
Enlarge outlet opening
•
Excessive flow quantity (pump capacity
too high)
•
Reduce flow quantity (adjust pump capacity)
•
The pond water is very dirty and the filter
pump is conveying an excessive amount
of dirt.
•
Thoroughly clean the pond.
•
Install the pump in an elevated position.
•
A large amount of dirt has entered the
filter system, water is flowing over
(instead of through) the foam filters.
•
Clean foam filters
Содержание Profi Clear Premium Compact L US
Страница 1: ...Pro Clear Premium Compact L US...
Страница 2: ...2 A ProfiClear0239...
Страница 3: ...3 B ProfiClear0243...
Страница 4: ...4 C ProfiClear0279 D ProfiClear0164...
Страница 5: ...5 E ProfiClear0129 F ProfiClear0130...
Страница 6: ...6 G ProfiClear0244 H ProfiClear0245 I ProfiClear0169...
Страница 7: ...7 J ProfiClear0240 K ProfiClear0280...
Страница 8: ...8 L EGC0009 M EGC0003 N ProfiClear0134...
Страница 9: ...9 O P PrifiClear0135 Q ProfiClear0041...
Страница 10: ...10 R ProfiClear0137 S ProfiClear0138...
Страница 11: ...11 T U ProfiClear0140 ProfiClear0141 V ProfiClear0139...
Страница 110: ...110 Proficlear0251 Proficlear0252...
Страница 112: ...112 Proficlear0254 Proficlear0255 Proficlear0256...
Страница 114: ...114 Proficlear0259...
Страница 116: ...76481 01 20...