background image

 

“NET” 

Appears when the display value is net 

“lb” 

Appears when the weight unit selected is “pound”     

“kg” 

Appears when the weight unit selected is “kilogram”     

 

 

4. Installation connection   

4.1

 If power adapter input, for its pole, see Figure 4a. 

 

                                       

 

                                           

Figure 4a: Power adapter input

 

4.2

 Load cell input 

4.2.1 If the 5-core aerial outlet is used for the load cell connecting, see Figure 4b. 

                                           

 

                     

 

 

Figure 4b: Wire-connecting between load cell and 5-core aerial pin-outlet 

 

4.2.2 If the 9-core D-shape plug is used for the load cell connecting, see Figure 4c. 

       

 

           

 

Figure 4b: Wire-connecting between load cell and 9-core D-shape plug 

 

Note: 

Make sure that the connection between the load cell and the indicator is reliable and the shield wire for the 

load cell is reliably grounded. Don’t insert or pull the plug of the connection cable under power-on state for 

the indicator, lest the static electricity damages the indicator or the load cell. Never process the welding or 

the other heavy- current operation on the indicator directly. 

 

Содержание HL-2065

Страница 1: ...XK3101 HL 2065 Indicator User s Manual...

Страница 2: ...uction 2 4 Installation Connection 4 5 Operation Keys Instruction 4 6 Use Instruction 5 6 1 Turn on Operation 5 6 2 Turn off Operation 5 6 3 Zeroing 5 6 4 Deducting Tare 5 6 5 Conversion between kg an...

Страница 3: ...drift 12 ppm 1 4 A D conversion resolution ration 300000 1 5 Display resolution ration 30000 1 6 A D conversion rate 100T S 1 7 Display shift rate 5T S 1 8 Non linearity 0 01 F S 1 9 Load cell excitin...

Страница 4: ...101 HL 2065C 1 5kg 2 Main Functions 2 1 Full keyboard calibrating 2 2 Zero position auto tracking 2 3 Full range deducting tare 2 4 Over load indicating 2 5 Simple counting 2 6 Two kinds of calibratio...

Страница 5: ...4 Figure 1 XK3101 HL 2065B Figure 2 XK3101 HL 2065C 3 2 Panel...

Страница 6: ...icating light MODE key TARE ENTER key ZERO key PRINT ON OFF key 3 3 Cursors and their meanings There are 6 LED indicating cursors on this indicator for the names and meanings see the following table C...

Страница 7: ...ween load cell and 5 core aerial pin outlet 4 2 2 If the 9 core D shape plug is used for the load cell connecting see Figure 4c Figure 4b Wire connecting between load cell and 9 core D shape plug Note...

Страница 8: ...print signal MODE key a Used for converting the mode between weighing and counting b Under calibrating state you can use this key to choose the setup method or the given parameter table also use it to...

Страница 9: ...goods weight is 0 5kg can be regarded as tare Press TARE 0 00 The tare has been deducted and at this time the NET indicating cursor appears Remove the goods 0 50 The indicator displays the tare negat...

Страница 10: ...t the same time 6 7 RS 232 Output 6 7 1 The 3 core aerial outlet is used for RS 232 hardware interface and the outlet is mounted on the back housing of the indicator see the following drawing Figure 5...

Страница 11: ...s weight D0 1 net weight State C output empty case character 6 7 3 Every frame consists of 10 digits The first is start bit 0 The ninth is stop bit 1 One of the other eight is correction bit and the o...

Страница 12: ...s used for selecting digit place and the digit of the selected place will flash at this time if you press the flashing digit of the selected place will be changed in 1 2 3 9 0 1 sequence For instance...

Страница 13: ...ct the setup value of the products leaving the company 7 6 Turn off its power at once if the indicator is out of order in use Non specialized manufacturer or non professional staff can t fix it withou...

Страница 14: ...he weight value on arbitrary point 8 2 Entering calibration or ambient data group CAL X refers to fixed point calibration arbitrary point calibration no calibration you can use to select the calibrati...

Страница 15: ...IV data for about 2 seconds At this time you can press to select the division and then press ENTER to confirm After the operation is finished the indicator enters zero load adjustment state For the ra...

Страница 16: ...Ad LD Load the weights on the scale platform after the indicator display Ad LD for 2 seconds Await 10 seconds make sure that the indicator is fully stable then press ENTER to confirm at this time the...

Страница 17: ...etup F2 X refers to auto zero tracking range X 0 5 1 0 2 0 3 0 d The auto zero tracking function can auto compensate the zero point change caused by the factor that a little material to be weighed dro...

Страница 18: ...e wave filtering strength the quicker the indicator response speed and the less stably the indicator works On the other hand the higher the wave filtering strength the slower the indicator response sp...

Страница 19: ...he indicator enters F9 setup F9 X refers to user s setup confirming or return to factory setup data X 0 confirm the user s setup data X 1 return to the factory setup data See the following table for t...

Страница 20: ...icator displays 0 000 00 the flashing 0 at the first digit on the last left is the selected digit Load 20kg rectification weights on the scale platform press twice to select the digit input place the...

Отзывы: