11
Figure 7: Bill mode
6.8.2 Connection between the indicator and the printer
Connect an end of printer cable to the D-shape 25-core joint (pin) for the printer and the other end
to 5-core metal outlet for the indicator. See the following drawing.
Figure 8: Connection between the indicator and the printer
6.8.3 Printing pattern Instruction
A. When the net weight is negative, it doesn’t print.
B. The order number is “0~99”. It automatically returns to zero when the number is over 99.
6.9
Digit Input
While processing the calibration operation, you need to input the digit. The digit input is all fulfilled
via [→] and [↑] key in cooperating. [→] refers to place-shifting key, it is used for selecting digit place
and the digit of the selected place will flash, at this time if you press [↑], the flashing digit of the
selected place will be changed in “
1
→
2
→
3
→
………
→
9
→
0
→
1
” sequence.
For instance:
How to input digit “001500”!
If the display content on the indicator is 030000 when digit input, the digit input steps
are as follows:
Step 1:
Press [→] once to make the indicator clear, at this time the digit at the last right flashes and the
indicator displays 00000“0”.
Step 2:
Press [→] once, the second digit at the last right flashes and 0000“0”0 is displayed.
Step 3:
Press [→] once, the third digit at the last right flashes and 000“0”00 is displayed.
Step 4:
Press [↑] five times, the indicator displays 000“5”00 and “5” flashes.
Step 5:
Press [→] once, the fourth digit at the last right flashes and 00“0”500 is displayed.
Step 6:
Press [↑] once, the indicator displays 00“1”500 and “1” flashes.