Open
Vertical
Electric
10
www.nuvair.com
Before carrying out any work on the compressor, each operator must have a perfect
understanding of how the compressor works, know how to use the controls, and have read
the technical information contained in this manual.
It is forbidden to use the compressor under conditions or for purposes other than those
indicated in this manual and Nuvair cannot be held liable for breakdowns, problems or
accidents caused by failure to observe this rule.
Check that the fittings provide a proper seal by wetting them with soapy water: Stop the
compressor and eliminate any leaks immediately when detected.
Do not attempt to repair high pressure tubes by welding them or while the compressor
is running.
Do not empty the bottles completely, not even during winter storage as this practice
allows damp air to get in and eventually corrode the bottle.
It is forbidden to tamper with, alter or modify, even partially, the systems and equipment
described in this instruction manual, especially as safety guards and safety symbols
are concerned.
It is also forbidden to carry out work in any way other than that described or to neglect
the illustrated safety tasks.
The safety information and the general information given in this manual are highly
important.
1.8
Where the Compressor may be used
The high pressure compressor model
Open Vertical Electric
has been designed and built for the
purpose of producing breathing air by drawing it from the surrounding environment. The
surrounding environment air must be free from any harmful fumes or contaminates. The air is
passed through an intake air filter, compressed and run through breathing air filtration before it is
stored in bottles constructed to contain air at high pressure.
The compressor must only be used in
environments having the characteristics described in the following table:
Area of Machine Use: Essential Data Table
Temperature ambient
Min. +41°F - Max. +113°F (Min. +5°C - Max. +45°C)
Air humidity
Maximum 80%
rain
Tolerated Weather Conditions
hail none
snow
Max tilt angle
6% grade (less than 4 deg.)
Check that the area in which the compressor is to be positioned is adequately ventilated:
good air exchange (more than one window) with no dust and no risk of explosion, corrosion or fire.
If ambient temperatures exceed 113°F (45°C) air conditioning will be required. Make sure that
lighting in the area is sufficient to identify every detail (such as the writing on the info
plates/stickers); use artificial lighting where daylight on its own is insufficient.
Содержание 8060
Страница 1: ...User Manual Open Vertical Electric MCH13 16 Rev 05 20 www nuvair com ...
Страница 2: ...Open Vertical Electric 2 www nuvair com ...
Страница 35: ...Open Vertical Electric 35 www nuvair com Service Log Date Technician Name Service Performed Machine Hours ...
Страница 37: ...Open Vertical Electric 37 www nuvair com Notes ...
Страница 38: ......
Страница 39: ...Open Vertical Electric 39 www nuvair com ...