Open
Vertical
Electric
17
www.nuvair.com
7.0
Unpacking and Installing
1) Please read all information supplied before physically installing the Compressor System.
2) Unpack the system and remove from the pallet. Visually inspect the system to make sure there has
been no damage during shipping. If damaged, please call Nuvair to file a damage report. Please
take photos and supply detailed information about the damage.
3) Place the system in a permanent location allowing a minimum spacing of 36” from adjacent walls.
Select a location where ambient room temperature is a minimum of +41°F to a m113°F
(°C Min. +5° - Max. +45°).
4) Make sure the installation space is well ventilated.
7.1
Electrical Connection (see section 15.0 for electrical specs)
Please read all information supplied before Connecting Electricity to the Compressor System.
You should hire a
licensed electrician
to install any electric compressors purchased from
Nuvair.
The compressor is delivered with raw leads ready to be installed into a junction box.
In the event a plug is needed, Nuvair recommends that the licensed electrician doing the install
determines the plug necessary.
Make sure your electrician follows approved and compliant standards for your location.
8.0
Daily Checks
Inspect the exterior of the compressor (couplings, pipes, pneumatic
components etc.)
Check for any oil leaks.
Replace parts where necessary or contact Nuvair
8.1
Lubricating Oil Level Check
Check that the level of lubricating oil is within acceptable limits (i.e. between min. and max.). Note
that an excessive quantity of oil can leave deposits on the valves while too low a level prevents
proper lubrication and could cause engine seizure. If the oil level is not within the minimum and
maximum limits top up or drain as described in section 15.1.
8.2
Check that Fill Hoses are in good condition
Inspect the refill hoses and make sure there are no cuts, holes, abrasions, leaks etc. If necessary
replace with new hoses.
9.0
Storing Technical Documentation
The use and maintenance manual and its appendices must be stored carefully and must always be
kept where they can be accessed easily for immediate review.
This User Manual contains important safety information and should always be available to
those personnel operating this equipment. Read, understand and retain all instructions before
operating this equipment to prevent injury or equipment damage.
Содержание 8060
Страница 1: ...User Manual Open Vertical Electric MCH13 16 Rev 05 20 www nuvair com ...
Страница 2: ...Open Vertical Electric 2 www nuvair com ...
Страница 35: ...Open Vertical Electric 35 www nuvair com Service Log Date Technician Name Service Performed Machine Hours ...
Страница 37: ...Open Vertical Electric 37 www nuvair com Notes ...
Страница 38: ......
Страница 39: ...Open Vertical Electric 39 www nuvair com ...