17.1 Temperature Affect on Filter Life
*Replacement frequency changes with addition of more filter towers (increased filtration volume).
Filter replacement frequency calculation table to provide
Breathing Air at CGA Grade E – MCH13/16
(Single SC000440-MHC filter cartridge)
Temperature
(°F)
Temperature
(°C)
Filter duration
(hours)
Filter duration
(hours)
(filter inlet air temp)
MCH-13
MCH-16
104
40
8.5
7
95
36
11.5
9.5
86
30
14.5
12
80
27
16.5
14
68
20
25.5
21.5
50
10
46.5
39
Filter replacement frequency – MCH-13 Tropical Blocks
(Calculations for Single CAN 35 Tower with X65247 Filter)
Temperature
(°F)
Temperature
(°C)
Filter duration
(hours)
Filter duration
(hours)
(ambient air temp)
MCH-13 Mk I
Tropical
MCH-13 Mk II
Tropical Plus
122
50
10
20
104
40
17
34
86
30
28
56
68
20
50
100
50
10
60
120
41
5
70
140
32
0
80
160
Filter replacement frequency – MCH16 Tropical Blocks
(Calculations for Single CAN 35 Tower with X65247 Filter)
Temperature
(°F)
Temperature
(°C)
Filter duration
(hours)
Filter duration
(hours)
(ambient air temp)
MCH-16 Mk I
Tropical
MCH-16 Mk II
Tropical Plus
122
50
8
16
104
40
14
28
86
30
23
46
68
20
40
80
50
10
48
96
41
5
56
112
32
0
64
128
Содержание 8060
Страница 1: ...User Manual Open Vertical Electric MCH13 16 Rev 05 20 www nuvair com ...
Страница 2: ...Open Vertical Electric 2 www nuvair com ...
Страница 35: ...Open Vertical Electric 35 www nuvair com Service Log Date Technician Name Service Performed Machine Hours ...
Страница 37: ...Open Vertical Electric 37 www nuvair com Notes ...
Страница 38: ......
Страница 39: ...Open Vertical Electric 39 www nuvair com ...