6.0
Compressor Specifications
Model
Open Vertical MCH13
Open Vertical MCH16
Fill Time*
Approx. 11 Minutes
Approx. 9 Minutes
Charging Rate*
8.4 SCFM (238 L/min)
11.3 SCFM (320 L/min)
CFM FAD
7 CFM (200 L/min)
9.4 CFM (266 L/min)
208-230 V / E1 / 50 or
60Hz**
25 amps 5.5 hp (4 kW)
Model# 8040.1
34 amps 7.5 hp (5.5 kW)
Model# 8061.1
208-230 V / E3 / 50 or 60
Hz**
14 Amp 5.5 hp (4 kW)
Model# 8040.2
20 Amp 7.5 hp (5.5 kW)
Model# 8061.2
440-480 V / E3 / 60 Hz
7 Amp 5.5 hp (4 kW)
Model# 8040.3
10 Amp 7.5 hp (5.5 kW)
Model# 8061.3
RPM
1200
1450
Sound Level @ 3 Meters
81 dB
80-96 dB
Max Operating Pressure
5000 psi (345 bar)
Number of Stages
3
Number of Fill Hoses
1-2
Condensate Drain
Manual (Auto Drain Optional)
Dimensions (L x W x H)
32 x 36 x 52 in (81 x 91 x 132 cm)
Weight
410-420 lbs (186-191 kg)
Lubrication
Splash lubrication, capacity 1.8 L
Air Quality
DIN 3188 - CGA Grade E - NFPA 1500 - EN12021
*Based on 80 cu ft cylinder from 500 to 3000 psi. **Model based on 60 Hz models, for information on 50 Hz models, contact Nuvair.
Ambient room temperature should never exceed 113
o
F (45
o
C) during operation of the
Compressor System. Operation at higher temperatures may lead to system damage and
malfunction.
Содержание 8060
Страница 1: ...User Manual Open Vertical Electric MCH13 16 Rev 05 20 www nuvair com ...
Страница 2: ...Open Vertical Electric 2 www nuvair com ...
Страница 35: ...Open Vertical Electric 35 www nuvair com Service Log Date Technician Name Service Performed Machine Hours ...
Страница 37: ...Open Vertical Electric 37 www nuvair com Notes ...
Страница 38: ......
Страница 39: ...Open Vertical Electric 39 www nuvair com ...