LIFT MAINTENANCE
Before beginning any maintenance work: Locate the power supply
main switch and turn off. Lockout and tag out to prevent re-
energizing system during maintenance. Secure the danger area
around the Lift and secure the Lift with safety stands to guards
against unintentional lowering.
PART
ACTION/PRODUCT
Clean the Piston-Rod.
Use compressed air.
Check the condition of the Equalizer Cables.
If cables are damaged or show any broken strands, replace the
complete cable-set.
If cables are slack, readjust per the installation instructions on page
20.
Clean and lubricate all moving parts of the Lift
including hinge bolts, sliding pieces, and sliding
surfaces.
Use a multipurpose grease.
Check Oil Level.
Fill the tank with clean AW32 Hydraulic Fluid
Change the hydraulic oil at least once a year.
To change the oil, lower the Lift to its lowest position.
Empty tank and refill with clean oil. Approximately 4 Gallons.
(If ambient temperature is under 40 degrees Fahrenheit, use lower
than 32 viscosity.)
Dispose of used oil according to the appropriate regulations.
Check all welded joints for cracks.
If any cracks are found on the Lift, stop use immediately. Switch-off
and secure the main switch (lock) and call service provider.
Check condition of Rubber-Pads on the arms.
Check for cracks or missing rubber.
Replace as needed.
Check all external surfaces for damage.
If damaged, repair immediately. If repairs are not made
immediately, permanent damage to the powder-coated surface may
result.
Repair and clean damaged areas with an abrasive paper (120 grit).
Coat repaired area with a suitable paint (observe the RAL Number).
Check Zinc Surface. White rust can result from
moisture laying in certain areas for long periods of
time or poor ventilation. Poor ventilation can also
result in rust formation. Rust may result from
mechanical damage, wear, aggressive sediments (de-
icing salt, liquids), or insufficient cleaning.
Repair and clean these areas with abrasive paper (240 grit). Coat
repaired area with a suitable paint (observe the RAL Number).
Check all safety devices.
All Safety Devices must be in good working condition. If not, contact
Technical Service.