31
T 01460 68600
Failure to rectify the problem or in the event of a breakdown contact your Numatic dealer or
Numatic Technical he44 (0)1460 269268
Specifications
Trouble Shooting
Model - TGB 6055 & 6055T
Brush
Motor
Vac
Motor
Brush
Sizes
Pad
sizes
Net
Weight
Gross
Weight (Full)
300 W
400 W
550 mm
508 mm
80 Ah - 156 Kg
100 Ah - 165 Kg
80 Ah - 216 Kg
100 Ah - 225 Kg
Traction Drive
Motor
Net Weight 6055T Model
Gross Weight (Full) 6055T Model
Maximum Climbing
Gradient 6055T Model
250W
80 Ah - 163.5 Kg,100 Ah - 172.5 Kg 80 Ah - 223.5 Kg, 100 Ah - 232.5 Kg
Scrubbing 9 %
Protection
Class
Run Time
Water
Capacity
Fluid
Flow
Noise
Maximum Climbing
Gradient
IPX4
2.25 hrs MAX
60 L
0 - 2 L/Min
71.4
dB(A)± 3dB(A)
Scrubbing 2 %
Brush
Speed
Scrub Pressure
Standard
Scrub
Pressure Heavy
Dimensions
Hand Arm
Vibration
Re-charge
Time
Charger
Drive
Speed
100
Rpm
24 Kg
32 Kg
Width = 560 mm
Length = 1425 mm
Height = 1120 mm
6055-0.44 m/s
2
6055T-0.57 m/ s
2
8 hrs
10 Amp
6055T
0-4Kph
PROBLEM
CAUSE
SOLUTION
Machine will not operate
Missing or blown fuses
Low battery charge
Machine is connected and charging
Waste tank full switch stuck or clogged
Key is off or missing
handle safety fuse blown
Fit or replace fuse (page 5)
Charge batteries (page 13 / 14)
Take off charge (page 13)
Inspect & clean switch inside tank (page 11)
Insert key & turn to operating position
Replace fuse (or contact service engineer)
Vacuum will not operate
Missing or blown fuse
Vacuum switch not engaged
Waste water tank full
Fit or replace fuse (page 5)
Press switch
Empty waste water tank (page 11)
Poor water pick-up
Waste water tank full
Clogged / blocked vacuum hose
Loose hose connections
Debris basket filter clogged / blocked
Separator filter clogged / blocked
Poor separator seal
Damaged separator seal
Damaged / split vacuum hose
Damaged floor tool blades
Low battery charge
Floor tool incorrectly adjusted
Empty waste water tank (page 11)
Remove and clean (page 11)
Push tight connections (page 7)
Remove and clean (page 11)
Remove and clean (Page 11)
Clean and refit (page 11)
Renew (contact service dept)
Renew (contact service dept)
Renew (contact service dept)
Re-charge batteries (page 13 / 14)
Adjust floor tool
No brush / scrub function
No brushes fitted
Brush deck raised
Lever not pressed
Missing or blown fuses
Check and fit (page 6)
Lower brush deck (page 9)
Press lever
Fit or replace fuse (page 5)
Little or no water flow
Clean water tank empty
Clean water tank filter blocked / clogged
Water flow not on
Brush deck raised
Tap not opened
Solenoid blocked
Fill clean water tank (page 7)
Remove and clean (11)
Switch on water flow (Page 9)
Lower brush deck (page 9)
Open tap to desired flow
Clean solenoid seal
Machine just ‘stops’ during
operating
Too much load on the brush system
Brush motor fuse blown due to high load
Handle safety fuse blown
Decrease the brush load to best suit the
floor type (page 10).
Replace fuse & reduce load (page 5)
Replace fuse (or contact service engineer)
Содержание TGB 6055
Страница 53: ...53 T 01460 68600 EU Declaration of Conformity...
Страница 54: ...54 T 01460 68600 Schematic Diagram Notes...
Страница 55: ...55 T 01460 68600 Notes...