background image

 

3. LIGHTING & CONTROLLING THE FIRE 

 

3.1 General 

The fire is available with 2 Control Options:  
Option a) The Nu-Flame Thermatronic (Fully Sequential) Radio Frequency Electronic Control System. 
The fire is fully operated using the Handset. 
Option b) The Nu-Flame Thermostatic Thermatronic (Fully Sequential) Radio Frequency Electronic Control System. 
The fire is fully operated  using the Handset but also the Handset allows you to do control the temperature of the room during the day or 
night, and timer programs.   
Both Control Systems are battery operated that use a microprocessor to provide the working sequences needed by the fire, and when 
used with an oxypilot have all the safety features required by law and CE approval. 
Commands are accepted by the microprocessor when buttons are pressed.  An audible beep means that the command is received, 
and the push buttons should then be released.  
                                                                                                   

3.2 Using the Thermatronic RF System 

      Control can only be achieved if the Handset is pointed at the Fire. 
      The red light will flash each time you press the Handset. 

a. Ignition. 

Simultaneously press and hold the red/off and the large flame button (linked by arrow) until a  

    short acoustic signal confirms that the sequence has begun, then release the buttons.   
    Continuous audible signals confirm that ignition is in progress.  
    When pilot ignition is confirmed the motor will open the valve to maximum flame height – this takes about 
    30 seconds. The main burner will then light at the high flame setting. 

b. Flame Height Adjustment. 

Press the small flame button until the flame height is at the desired position.  

    If you try to go beyond the preset low flame setting the fire will turn off leaving the pilot burner alight  
    (This is the standby position).   
    You will learn from experience how to achieve the minimum preset low flame setting. 

c.

 

Relighting the Fire. 

To relight the fire from the standby position, or to increase the flame setting from low  

    flame, simultaneously press the red/off button and large flame buttons (linked by arrow).   
    Please note that you can have the flame height anywhere between maximum and preset low.   
    For fine adjustment simply tap the large and small flame buttons. 

d. Switching Off. 

Press the red/off button. 

 

3.3 Using the Thermostatic Thermatronic RF System 

     Control can only be achieved if the Handset is pointed at the Fire. 
    You will see that the Handset as a screen with symbols and reference should be made to the following screen settings for each  
     stage of operation. 
    With the fire in the off position the screen will look as shown below. 
    This is the Manual Setting display and will be used to first light the fire. 
    The screen shows the following: 
 
 
 
                      
 
                                                                                                                                       
 
                     
             
 
 
 
 

a. Ignition. 

Simultaneously press the Off and Large Flame Buttons (linked by the line/star symbols) until  

    a short acoustic signal confirms that the sequence has begun, then release the buttons.   
     Continuous audible signals confirm that ignition is in progress.  
    When pilot ignition is confirmed the motor will open the valve to maximum flame height – this takes 
    about 30 seconds. The main burner will then light at the high flame setting. 

b. Flame Height Adjustment. 

Press the small flame button until the flame height is at the desired  

    position. For fine adjustment tap the Large Flame or Small Flame buttons 
    If you try to go beyond the low flame setting the fire will turn off the main burner leaving the pilot burner alight  
    (This is the standby position).    
    You will learn from experience how to achieve the minimum low flame setting. 

c.

 

Relighting the Fire. 

To relight the fire from the standby position, or to increase the flame setting  

    from low flame, simply press the large flame button.   
    Please note that you can have the flame height anywhere between maximum and low.   
    For fine adjustment simply tap the large and small flame buttons. 
Note: You can also automatically set the fire at either Tall or Low Flame setting by pressing the desired flame Button twice.  

d. Switching Off. 

Press the off button

 

 
You can now proceed to the other features of the Handset such as Setting the Time, Temperature and Time Programmes.  

 

 

 

  Note:  Radio Frequency Symbol Shows Only When Pressing Handset  
    
   Room Temperature                                                                    Battery Charge Level 
                                                                                                     
    Handset in Manual                                                                             
            Setting 

Time of Day 

Содержание SYNERGY ELLESSE

Страница 1: ...FIRE IS HEAVY AND ASSISTANCE SHOULD BE SOUGHT WHEN LIFTING ALL INSTRUCTIONS MUST BE LEFT WITH THE USER FOR SAFE KEEPING MANUFACTURED by Nu Flame Limited Unit 4 Kimpton Trade Business Centre Minden Ro...

Страница 2: ...12 Hole in the Wall Installations for Steel Glass Trim Styles 12 With Appropriate Sealing Frame 13 Hole in the Wall Installations for Echo Trim Style 14 14 Hole in the Wall Installations with Marble...

Страница 3: ...rone to being chipped or scratching 1 2 Removal of Components a Fires Ordered with Steel or Glass Trims i The Outer Door will have to be removed and stored carefully to allow access for removal of the...

Страница 4: ...he Fire can be installed into a suitably designed fire surround with a 150 C Rating v Take care with some Micro Marble Materials claiming a 150 C Rating as they may give off odours blister or discolou...

Страница 5: ...nked by arrow Please note that you can have the flame height anywhere between maximum and preset low For fine adjustment simply tap the large and small flame buttons d Switching Off Press the red off...

Страница 6: ...esent room temperature the fire will go straight to the Standby Setting until the temperature drops below the Set Temperature at which point the main burner will relight Note The Room Temperature is s...

Страница 7: ...ELDERLY OR INFIRM OR PETS ARE LEFT IN ATTENDANCE 3 5 RESETTING THE MERTIK MAXITROL LOGIC CIRCUITS IF THE HANDSET DOES NOT WORK APPLIES TO BOTH CONTROL SYSTEMS Must only be done when the fire is Cool B...

Страница 8: ...of the door Follow instructions in section b above e The logs must not be cleaned or moved f The outer surfaces of the fire can be cleaned with a damp lint free cloth do not use abrasive cleaners IMPO...

Страница 9: ...FORE PROCEEDING WITH THE INSTALLATION READ THESE INSTRUCTIONS CAREFULLY THESE INSTRUCTIONS SHOULD BE LEFT WITH THE USER FOR SAFE KEEPING AND FUTURE SERVICING PRIOR TO INSTALLATION ENSURE THAT THE GAS...

Страница 10: ...Height mm Synergy Ellesse Echo Trim with Metal Door 1140mm 540mm Synergy Ellesse Echo Trim with Glass Door 1140mm 540mm Synergy Ellesse Steel Trim No Sealing Frame 1135mm 560mm Synergy Ellesse Steel...

Страница 11: ...PPLIANCE SEEK EXPERT ADVICE 10 VENTILATION a No additional purpose provided ventilation is normally required for the fire when installed in the UK however this must be confirmed by the Spillage Test s...

Страница 12: ...rials d No combustible materials must present in the builders opening e The base of the builders opening must be flat level and square to the wall f The builders opening should have provision for a ga...

Страница 13: ...rs opening d If the silicone sealing strip is not compressed and there are gaps they must be filled with a suitable sealant fireclay or high temperature silicone Wall staining may occur if the seals a...

Страница 14: ...placed too close e No combustible material e g curtains must be closer than 500mm to the builders opening The wall between the sealing frame and any shelf would become hot Therefore we do not recomme...

Страница 15: ...with a suitable sealant fireclay or high temperature silicone j Refit the burner mounting plate assembly by first putting the Receiver through the opening then tilt the assembly and slide it into the...

Страница 16: ...ng structural check may be required c The builders opening must be constructed from Non combustible materials d No combustible materials must present in the builders opening e The base of the builders...

Страница 17: ...ay in position to make a seal against the top edge of the slip at the base of the builders opening and the front face of the slips where they locate against the rear of the Fire outer frame While slid...

Страница 18: ...any rendering building work is allowed to thoroughly dry out before Installation IMPORTANT Dry lined walls ensure that any air gaps between the back of the plasterboard and wall are sealed around the...

Страница 19: ...slightly and slide it home ensuring that the sealing strips on the underside of the front riser channel and the rear of the Fire outer frame stay in position to make a seal against the base of the fi...

Страница 20: ...y Breast will occur e The Wall Mounted Television must be mounted on a suitable bracket or angled bracket that meets the Television Manufacturer s requirements and spaces the Television at least 35mm...

Страница 21: ...osition for a Wall Mounted Television Must meet the Installation Requirements of these Instructions e The Nu Flame Television Glass Heat Shield is only suitable for the Nu Flame Synergy Range of Gas F...

Страница 22: ...the Fire s Installation Instructions and the Fire Surround meets the Minimum Dimensions as detailed in the Diagrams Below b You Must take account of the Television Manufacturer s Installation requirem...

Страница 23: ...fuel tray g Place the large rear log No 1 to the rear of the fire on the fuel tray ensuring that the cut out in the log sits behind the pilot shield and that it is central about the burner h Place lo...

Страница 24: ...n the log support at the front k Place log No 5 next to log No 6 locating it on the peg and the cut out in the rear log l Place the last log No 4 so that it locates on the central peg and rests in the...

Страница 25: ...Emberglow material is a consumable material and as a limited life You can buy replacements through your local Nu Flame Ltd Stockist or Installer q For Synergy Perspective Glass Wall Mounted Installati...

Страница 26: ...m or adjacent rooms running at high The fire should continue to clear its combustion products Also operate any other flued appliance in the same or neighbouring rooms and ensure they continue to funct...

Страница 27: ...ii Now secure the upper Hinge Pin with the fixing screw provided as shown the door should then be closed and held shut by the magnet catches Very Important The Hinge Pin Screw Must be fitted to ensur...

Страница 28: ...SES WHEN LIT 20 SERVICING 20 1 GENERAL Note Servicing must be carried out by a registered installer a The fire does not have to be removed for Servicing b Check the operation and ignition of the fire...

Страница 29: ...Burner Control Assembly to Nu Flame for rectification as this could be the least cost option 21 3 PILOT GOES OUT AFTER FIRST LIGHTING a Check there is no vermiculite blocking the flame to the thermoco...

Страница 30: ...ork d Change the Handset and or Receiver and or Burner Control System Important In instances where it is indicating that either of the main control systems need changing you should investigate returni...

Страница 31: ...5 4 The fire must be Installed serviced by a properly qualified in accordance with Local National Codes Installation Engineer and in accordance with these Installation Instructions Supplier Nu Flame L...

Страница 32: ...fire must be Installed serviced by a properly qualified in accordance with Local National Codes Installation Engineer and in accordance with these Installation Instructions Supplier Nu Flame Limited...

Страница 33: ...33 23 DIAGRAM OF INFRARED CONTROL SYSTEM...

Страница 34: ...elivery to us We will not be liable for any such breakages or losses Under no circumstances should any attempt be made to repair the burner on site without our express knowledge and approval during th...

Отзывы: