13
12.3 – CLEARANCES TO SHELVES & COMBUSTIBLE MATERIALS
a.
We do not recommend the use of combustible shelves in this application.*
b.
We do not recommend the use of a
non-combustible
shelf in this application. However, see section 13 which shows the
application where a
non-combustible
shelf is used.*
c.
Any combustible sidewall must be at least 500mm from the inside of the builders/fireplace opening.
d.
With all heating appliances, soft furnishings, decorations and wall coverings may discolour or scorch if placed too close.
e.
No combustible material, e.g. curtains must be closer than 500mm to the builders opening.
*The wall between the sealing frame and any shelf would become hot. Therefore, we do not recommend any shelves with this type
of installation.
12.4 - FITTING THE FIREBOX
a.
It is very important that the sealing frame makes a good seal against the wall to ensure the fire can seal against the Sealing
Frame. There is silicone sponge sealing strip already affixed to the relevant surfaces of both items to ensure a good seal.
Ensure this silicone sealing strip stays in place during installation.
b.
Secure the Sealing Frame to the wall with the screws and rawlplugs provided ensuring it is positioned centrally in the Builders
Opening.
c.
Make sure that the silicone sealing strip stays in position, around the flange on the Sealing Frame, to create a seal to the wall
around the builders opening.
d.
If the silicone sealing strip is not compressed and there are gaps they must be filled with a suitable sealant, fireclay or high
temperature silicone. Wall staining may occur if the seals are not compressed and the flue draw will be compromised.
e.
Slide the Fire
part way
through the Sealing Frame (leaving it sticking out approximately 50mm) ensuring the gas supply pipe and
isolation/pressure test elbow clears through the cut out in the rear of the Fire and does not foul on the control.
f.
Lift the Fire slightly and slide it home ensuring that the sealing strip along the front edge of the underside of the Fire
stays in
position to make a seal between the Fire and the sealing frame
.
g.
Ensure that the silicone sealing strip on the rear of the Fire outer frame stays in position to create a good seal between the Fire
and the Sealing Frame.
h.
Secure the Fire to the Sealing Frame with the screws provided.
i.
Refit the burner mounting plate assembly by first putting the Receiver through the opening then tilt the assembly and slide it into
the fire and secure with the 4 screws. Take care not to mark the liners in the fire. Place the Receiver to the left side at the front.
j.
Connect the isolation/pressure test elbow to the control valve and with it fully open check the joint for gas soundness.
k.
Check that all gas connections are sound. The appliance has been factory tested; however the connections may have been
disturbed in transit or storage.
! IMPORTANT NOTE !
Always reseal the pressure test point and check that it is gas tight.
(This accounts for a lot of recalls.)
Содержание SYNERGY ELLESSE