20
IMPORTANT: THE STEEL TRIM OPTION WHEN WALL MOUNTED IS NOT
SUITABLE FOR A WALL MOUNTED TELEVSION.
These Instructions detail the Installation Requirements for Wall Mounted Televisions when Installed
above the Fire and should be considered with all other Installation Requirements of the Fire.
IMPORTANT: Due to the High Heat Output of the Fire The Installation Requirements of these
Instructions MUST be Adhered To For Wall Mounted Televisions.
IMPORTANT: The Fire and Trim Style will affect the height and position of the Television therefore it
is important to check what height position options are possible and acceptable.
16.1 - GENERAL
Before continuing with the Television Installation it is important to determine if there is the likelihood of the Chimney Breast
becoming hot when the Fire is in operation. Some of these checks will only provide assistance if a fire has been previously
installed. The following checks will assist but are not conclusive.
a.
Typically Class 1 flues with Dry Lined Walls will normally have acceptable Wall Temperatures provided the air gap is fully sealed
around the builders opening.
b.
If a gas fire was installed and the chimney breast shows any signs of over heating e.g. discoloured wall paper, then do not
consider Installing a Wall Mounted Television as the Temperatures are likely to be too high.
c.
If a gas fire was installed and the Chimney Breast is finished in Wall Paper and shows no signs of temperature damage
then the Wall Temperatures are likely to be acceptable so the Installation can proceed.
d.
A Wall Mounted Television Must Not be sunk into the wall as it will not be in an acceptable ventilated position and this is only
acceptable if additional fan cooling ventilation is provided. It is also likely that higher temperatures from the flue within the
Chimney Breast will occur.
e.
The Wall Mounted Television must be mounted on a suitable bracket or angled bracket that meets the Television Manufacturer’s
requirements and spaces the Television at least 35mm away from the Chimney Breast.
f.
After reading the Installation Requirements you should compare this with the preferred height position of the Television.
16.2 - TELEVISION GLASS HEAT SHIELD INSTALLATION REQUIREMENTS
Reference Must Also Be Made to the Installations Requirements for Each Type of Trim as Detailed on the Following Pages
Where the Installation requires the fitting of the Television Glass Heat Shield the following instructions apply.
Important
- Before proceeding with the Installation of the Television Heat Shield confirm the preferred Height Position of the
Television with the Customer.
a
. It is recommended that, for aesthetic reasons, due consideration is given prior to Installation for the provision of main s
electric, aerial, sound and any other Connections that may wish to be hidden behind the Television.
A Qualified Electrician/Specialist should be consulted.
b.
Reference should be made to the diagram below for the position of the hole fixings which should be above the minimum
height as shown in the different Installation Requirements on the following pages.
c
. Determine the height position to the base of the Television Heat Shield from the relevant Installation Diagrams on the nex t
page and draw a line for reference ensuring it is level.
d
. Mark out the holes as shown in the diagram but before drilling recheck your dimensions ensuring the height of the
Television is correct and the distances will be as required.
e
. Before drilling the holes check for the positions of any wires within the wall
f.
Ensure the wall is sound and the fixings will be secure for the Television Heat Shield before proceeding with fitting.
16. INSTALLATION INSTRUCTIONS FOR WALL MOUNTED TELEVISIONS
ADITIONAL REQUIREMENTS
Television Heat Shield Fixing Hole Centres
Ensure the Base is at the Correct Distance
Содержание SYNERGY ELLESSE
Страница 33: ...33 23 DIAGRAM OF INFRARED CONTROL SYSTEM...