INSTALLATION AND SERVICING INSTRUCTIONS
6. INSTALLATION REQUIREMENTS
THIS APPLIANCE MUST BE INSTALLED AND SERVICED BY A PROPERLY QUALIFIED, (IN ACCORDANCE WITH LOCAL &
NATIONAL CODES), INSTALLATION ENGINEER.
It is the Law in the UK that All gas appliances are installed by a competent person in accordance with the GAS SAFETY(INSTALLATION
AND USE ) REGULATIONS 1998 (As amended), the relevant British Standards for Installation work, Building Regulations, Codes of
Practice and these Instructions . In the UK a Registered Installer is deemed competent. In the Republic of Ireland, all Irish Standards,
Local Codes and Bord Gais recommendations should be adhered to.
The Installation should also be carried out in accordance with the following where relevant:
1. BS5871 Part2 2. BS5440 Parts 1& 2 3. BS6461 Parts 1&2 4. BS6891 5. BS8303
Building Regulations and Standards issued as relevant by the Department of the Environment or the Scottish Development
Department.
In the Republic of Ireland Installation should be carried out in accordance with IS813, ICP3, IS327, Building Regulations, Codes of
Practice, these Manufacturers Instructions and any Rules In Force.
Particular Reference should be made to the Ventilation Requirements, for the UK this Appliance would not normally require any
additional purpose provided ventilation, for the Republic of Ireland ventilation should be in accordance with IS813 Domestic Gas
Installations.
Failure to comply with the above could leave the Installer Liable to Prosecution and Invalidate the Warranty.
IMPORTANT
BEFORE PROCEEDING WITH THE INSTALLATION READ THESE INSTRUCTIONS CAREFULLY.
THESE INSTRUCTIONS SHOULD BE LEFT WITH THE USER FOR SAFE KEEPING AND FUTURE SERVICING.
PRIOR TO INSTALLATION ENSURE THAT THE GAS TYPE AND PRESSURE ARE AS STATED ON THE APPLIANCE DATA PLATE.
7 APPLIANCE DATA
a.
Gas Type: See Data Plate, (Natural Gas at 20mbar or Propane at 37mbar).
b.
Burner Pressure: Natural Gas 19.3mbar hot Propane 34.6mbar hot
c.
Control Systems: Thermatronic & Thermotronic Thermostatic Control Systems operated by Handset pointed at Receiver.
d.
Fire Safety: Oxygen Depletion & Flame Failure Device.
e.
Ignition: Full Sequential Control.
f.
Inlet Connection: 8mm Compression Fitting to Gas Isolation Elbow.
g.
Category: I2H, I3P.
h.
Injector: Natural Gas (G20)-400 Multi hole. Propane (G31) - 240 Single hole.
i.
Heat Input: High: Natural Gas (G20) - 6.4kW Gross (5.77kW Net). Propane (G31) - 6.65kW Gross (6.12kW Net).
j.
Heat Input: Low: Natural Gas (G20) - 2.8kW Gross (2.5kW Net). Propane (G31) - 2.8kW Gross (2.6kW Net).
k.
Efficiency Class: 1 The Efficiency of this appliance has been measured as specified in BS7977-1:2009 and the results obtained
were 72.3% Gross (80.2% Net) on Natural Gas and 70.7% Gross (76.8% Net) on Propane. The test data has been certified by BSI
(0558) and can be used in the UK Government’s Standard Assessment Procedure (SAP) for Energy Rating of Dwellings.
l.
Heat Output: High: Natural Gas (G20) - 4.63kW Propane (G31) - 4.7kW
m.
Heat Output: Low: Natural Gas (G20) - 1.9kW Propane (G31) - 1.9kW
n.
Pilot ODS Type: Natural Gas (G20) - P461 0307. Propane (G31) - P477 0906.
o.
Nitrous Oxide (NOx) - 130mg/kWh
8 APPLIANCE DIMENSIONS with Optional Door and Frames
8.1
The Diagram below shows the General Fire Sizes fitted with the Steel Door with Sealing Frame.
For other Door and for Frame Style Options see the next page.