16.4 - TELEVISION INSTALLATION REQUIREMENTS FOR FIRES INSTALLED IN FIRE SURROUNDS
(Combustible or Non Combustible Fire Surround)
The Echo Trims Styles are Not suitable for a Traditional Fire Surround and will require a Bespoke Design.
As part of this design the 150mm minimum deep shelf and minimum height of 100mm must be maintained.
Note: The Installation Requirements for Combustible (e.g. Wood Mantel) are different to a
Non Combustible (e.g. Stone Surround). Refer to the Relevant Diagram Below.
Important: Due to the High Heat Output of the Synergy Range The Installation Requirements of these
Instructions Must Be Adhered To For Fire Surrounds with a Wall Mounted Television.
Important: Taking account of the minimum distance requirements in the diagrams below it is important that the
preferred position for the Television is determined before any building work is carried out.
Provided the shelf of the Fire Surround is at least 150mm deep then a Wall Mounted Television can be wall
mounted without a Television Glass Heat Shield or Top Shelf, however we would recommend that the Television is
mounted at least 100mm above the Surround.
Additional Requirements
a.
The Temperature above a Fire Surround has been verified by BSI to provide an actual Ambient Temperature of 90º Fahrenheit (32º
Centigrade) when the Synergy is Installed as detailed in the Fire’s Installation Instructions and the Fire Surround meets the Minimum
Dimensions as detailed in the Diagrams Below.
b.
You
Must
take account of the Television Manufacturer’s Installation requirements provided within their Instructions.
c
. The preferred height position for a Wall Mounted TV may only be possible with a specific design of Fire Surround.
d.
The Fire surround
Must
meet the Minimum Dimensions shown in the Diagrams to be suitable for a Wall Mounted Television.
e.
The Television can be Mounted Vertically if desired with a suitable Wall Bracket.
f
. Alternatively to help provide the preferred viewing position a 15
º
Angled Wall Mounting Bracket can be used for the Television
Installation. A wall bracket with a larger angle
Must Not
be used.
g
. It is recommended that, for aesthetic reasons, due consideration is given prior to Installation for the provision of main s
electric, aerial, sound and any other Connections that you may wish hidden behind the Television.
h
. Check First for the positions of any wires within the wall before drilling for the fixings.
i
. Ensure the wall is sound and the wall fixings are secure and able to take the weight of the Television.
j.
The Fire Surround and fixing requirements provided will ensure thermal protection through the critical central area therefore
will still be suitable for Wider televisions, however all other requirements of these instructions must also be adhered too.
Combustible Fire Surround Installation e.g.
Wood Mantel
Non Combustible Fire Surround
Installation e.g. Stone Mantel