Page 6
National Rejectors, Inc. GmbH, Germany
Manual G-26.4000: Technical Information 3/93
1 = 'Exact change' lamp lights up
(unchangeable)
1 = Committed to vend
0 = Uncommitted to vend
1 = External reset
0 = Internal reset
{
1 = Reset line 6
0 = Reset line 8
1 = Single vend
0 = Multi vend
4) Function 04 = Activate price table within G-26.4000 Simplex V
Using this function it is possible to set the prices within the G-26.4000 Simplex V. Thus the audit
data for the G-26.4000 Simplex V now include also the information referring vend/sales per price
line.
Prior to price setting it is necessary to activate the price table within the G-26.4000 Simplex V.
G-26.4000 Standard
(Only valid for
G-26.4000 Simplex V)
G-26.4000 Standard
* When programming this function please refer to the ' Manual for Changer Series G-26.4000'
function 04.
1 = Blocking of coins when 'tube empty'
(unchangeable)
{
1 = Erase remaining credit unable to be payed back
1 = Price setting with SIMPLEX V