Manual G-26.4000:
Page 58
National Rejectors, Inc. GmbH, Germany
or:
G-26.4000 Standard, G-26.4800 Professional:
o It is a fault, which cannot be removed immediately. However, the changer should remain in
operation. Therefore, for example, the other tubes have to be filled.
On the display appears:
* Key ‘F’
o Display shuts down
* Fill tubes (see page 18)
* To ensure that no customer gets less change due to the defective motor, initiate one payout
operation (function 01 = inventory) from the tube with the defective motor.
o The fault number appears temporarily on the display.
The changer remains in working condition. When change is given the tube with defective motor is not
operated. The acceptance of high valued coins is inhibited (function 17) and the LED ‘tube empty’
lights up.
G-26.4800 BDV-Standard without keyboard:
* Select function ‘filling of tubes’ on vending machine
control, then fill tubes.
Remedying Faults