Manual G-26.4000:
National Rejectors, Inc. GmbH, Germany
Page 14
5. Description of Operating Modes
Note:
The functions described hereafter can be set within units including the latest software. If
necessary, please contact NRI.
Mode
Reason
Select
o Inventory
- to relocate changer
01
- servicing
Emptying tubes- inventory
- transport
o Price setting
02
(G-26.4000 Standard)
o Machine number
02AU
o Acceptance limit
- prevents misuse as
0301
changemaker
All coins are inhibited once
acceptance limit is reached
o Change limit
- maintains change store
0302
Limited change given
Only effective within mode ‘multi-vend’
o Setting of tokens
Setting value of up to three
0303
different tokens possible.
o Single vend
Coins inserted for each vend.
04
Changer inhibits coin
Change given after each vend
acceptance, when credit exceeds
automatically
highest price.
o Multi-vend
More than one vend may be
04
made without inserting coins
Change after vends and
for each.
reject operation
o Committed to vend
Prevents misuse as changemaker
04
Vend must be made before
change given
o Uncommitted to vend
04
Change returned at any time
Functions