Manual G-26.4000:
Page 37
National Rejectors, Inc. GmbH, Germany
Diagnostics
Function 13 = Diagnostics
Action
Key
Display
* Select ‘Printout of
P
1304
data block’
* Printout
E
1304
¦¦
Connect printer and key ‘PRINT’ on printer
(Example of printout : see below)
* Select ‘Filling of tubesP
1305
through validator’
2.50
* Execute
E
1305
00.00
Existing credit is erased. Now insert coins to fill tubes.
Inserted coins are counted but not evaluated as credit.
* Select ‘Display of line
P
1306
conditions’
(G-26.4000 Standard)
* Execute
E
1306
(Example: vend line 1 active)
01
* Return to base function
F
13
* Return to standby
F
shuts down
Example of printout:
Reserve Byte
Language of Printout
Machine Type
Cigarette Mode
Lowest Coin Denomination
000130000010
001000500100
(left tube) (middle tube) (right tube)
001000500100
Coin Denomination Channels
0200050000D1
1 - 8
00000000FF
Data Block End
092002200004
Software Version
08:09
04.08.1992