Manual G-26.4000:
Page 15
National Rejectors, Inc. GmbH, Germany
Mode
Reason
Select
o External reset
04
(G-26.4000 Standard)
Vending machine provides
reset signal
o Internal reset
Price pulse 75 up to 100 msec
04
(G-26.4000 Standard)
No reset signal from
vending machine
o Reset via 6
Determined by machine.
04
(G-26.4000 Standard)
Only effective in connection
with ‘external reset’.
o Reset via 8
Determined by machine.
04
(G-26.4000 Standard)
Only effective in connection
with ‘external reset’.
Lamp ‘exact change’
Customer can buy, however, he
lights up (unchangeable)
possibly has to renounce his
residual money. Money which cannot
be paid back, will remain as credit.
Note:
o The ‘exact change’ lamp now solely depends on
the ‘tube empty’ condition, set on function 22.
o When coins are still in the tubes, they are paid out even in
case of 'tube empty' display.
o Residual credit, due to insufficient change, remains.
o Change is paid back in lowest number of available coins.
o Blocking of coins
Coins set by function 17
04
when ‘tube empty’
are not accepted when the
(unchangeable)
‘tube empty’ condition is
fulfilled.
o Display of time
When credit = 00.00 the
0401
time can be displayed.
Functions