National Rejectors, Inc. GmbH, Germany
Attention:
If within channel 12 a coin is programmed, the coin denomination within channel 9 must
not be sorted into the right tube as during inhibit of channel 12 (using switch 1) the sorting
changes from channel 9 to channel 8.
The
sorting function
- special function for validators with English coin acceptance - can be
activated by using switch 1,
- if within channel 12 no coin is programmed,
- if the coin denomination, accepted by channel 9, is guided into the right tube
* Move switch 1 on the 4-pole Dual-In-Line switch in the upper position
o Now coins accepted within channel 9 are no longer guided into the right tube, but coins
accepted within channel 8 are guided into the right tube.
G-10.4000/5