Initial Operation
6. Initial Operation
* Check
- supply voltage
- vending machine compatibility
- vending machine interface
* Connect earth wire to housing of vendor.
Good metallic contact is absolutely necessary.
* Connect changer
* Switch on
- external display shows 00.00 or time or residual credit
* Check operating modes are correctly set (function 04)
* Check that motors are in standby state (key ‘+’ twice)
* Fill each tube with at least 20 coins (see ‘Filling Change Tubes’ page 18)
* Check setting of time and date (function 14)
* Set prices (G-26.4000 Standard) and machine number (function 02)
* Check maximum change and credit (function 03)
* When tokens are accepted, check correct setting (function 0303)
* Check single coin inhibit (function 15)
* Check coin acceptance and correct credit display
* Test vend and check correct change dispenser
Changer is now ready for use.