background image

TC-10 User Manual 

________________________________________________________________________________________________________________

 

___________________________________________________________________________ 
version 3.9 

 

 

page 4 

2.  TC-10 Components 

 
The following items are shipped with the TC-10 system: 
 

 

TC-10 19” cabinet 

 

Power cord 

 

User manual 

 

Optional accessories: 

 

 

Miniature temperature sensor (TS-100) 

 

Subminiature temperature sensor (TS-200) 

 

Caution

: The temperature sensors are very sensitive to mechanical stress, especially to bending. 

Therefore, they must be handled with great care to avoid breaking of the insulation! 
 

 

Recording chamber 

 

HCS heated chamber stage 

 

ALA DIN connector cable assembly 

 

Thermal foil 

 

Objective heater 

 

HPC-G perfusion cube 

 

HPC-2 perfusion cube (low flow rate) 

 

3.  TC-10 System 

3.1. System  Description 

 
The TC-10

 

temperature control system is designed for heating purposes in electrophysiological 

experiments. The TC-10 system is housed in a 19 inch standard cabinet, with a built-in power 
supply and cooling elements for the power devices. The TC-10

 

guarantees low noise operation 

and has special protection features to prevent the preparation from damage. 
 
The TC-10 incorporates two electronic thermometers for small semiconductor sensors (R2252, 
i.e. the sensor has a resistance of 2252 

 at 25 °C), two digital temperature displays (XX.X °C), 

a set-point control with direct readout (XX.X °C), a PI (proportional-integral) controller with 
adjustable  parameters,  an  output  power  control  unit  and  a  high-power  output  stage  (DC, 
continuous operation) for resistive (i.e. heat only) loads with electronic protection circuits. The 
power  output  is  short  circuit  protected,  the  output  power  is  limited  electronically.  Maximal 
output voltage is approximately 12V, the current is limited to 5A. 
 
The system can be connected to the thermistors / heating elements in two ways:  

Using separate cables for the sensors and the heating element or 
Using the ALA DIN cable assembly that connects both, sensors and heating elements 

 
A large variety of sensors and thermal elements are available (see also 

Optional accessories

 in 

chapter 2). Please contact npi for details. 
 

Содержание TC-10

Страница 1: ...EM DESCRIPTION FOR THE TC 10 TEMPERATURE CONTROL SYSTEM VERSION 3 9 npi 2018 npi electronic GmbH Bauhofring 16 D 71732 Tamm Germany Phone 49 0 7141 9730230 Fax 49 0 7141 9730240 support npielectronic...

Страница 2: ...s 4 3 TC 10 System 4 3 1 System Description 4 3 2 Description of the Front Panel 5 3 3 Rear Panel Elements 10 3 4 Electronic Control and Protection Circuits 10 3 5 Modes of Operation 11 3 6 Setting th...

Страница 3: ...is to be operated only at 115 230 Volt 60 50 Hz AC Please check for appropriate line voltage before connecting any system to mains Always use a three wire line cord and a mains power plug with a prote...

Страница 4: ...ndard cabinet with a built in power supply and cooling elements for the power devices The TC 10 guarantees low noise operation and has special protection features to prevent the preparation from damag...

Страница 5: ...____________________________________________________________________________________ ___________________________________________________________________________ version 3 9 page 5 3 2 Description of t...

Страница 6: ...working temperature of the controller system 2 TEMPERATURE C A display Digital display to indicate the temperature determined by SENSOR A or the voltage at the POWER OUTPUT connectors 18 19 Switch 11...

Страница 7: ...to indicate that temperature SENSOR B 16 is not connected broken or short circuited The POWER OUTPUT 18 19 shuts down if this LED is on and the MODE switch 14 is set to SENSOR B 8 LIMITER potentiomete...

Страница 8: ...perature SENSOR A This connector also provides the POWER OUTPUT 18 19 for the heating unit max 12V DC and 5A for devices with the DIN connector cable assembly e g HPC G see www alascience com 14 MODE...

Страница 9: ...onnectors for the heating unit This output supplies a maximum voltage of 12V DC and a maximum current of 5A POWER OUTPUT is also available at the SENSOR A 13 and SENSOR B connectors 16 for devices wit...

Страница 10: ...output signal obtained from the thermometer giving an error signal This signal is amplified in the PI controller and transferred to the output stage where it is converted to a high power output signa...

Страница 11: ...de the output voltage is controlled by the PI controller PI proportional integral controller system activated The temperature signal which is used for the control unit is selected by the MODE switch T...

Страница 12: ...ystem the DESIRED TEMPERATURE can be set using the COMMAND INPUT 10mV C connector 10 Figure 1 The COMMAND INPUT is scaled 10mV C i e 370 mV at this connector would set the DESIRED TEMPERATURE to 37 C...

Страница 13: ...__________________________________________________________________ ___________________________________________________________________________ version 3 9 page 13 5 Temperature sensors Block diagram 5...

Страница 14: ...ft with a DIN connector on one end and two 1 mm connectors on the other end The DIN connector is for connection to the SENSOR input at the front panel of the temperature controller The 1 mm connector...

Страница 15: ...__________________________________________________________________________________________ ___________________________________________________________________________ version 3 9 page 15 5 2 Block dia...

Страница 16: ...the instrument Turn all potentiometers to the most left position switch the MODE selector to the position SENSOR A or B depending on which sensor is used as feedback temperature in the controller loop...

Страница 17: ...TION Thus when beginning to use the TC 10 we recommend to try out several first settings of GAIN and INTEGRATION to find out which settings are best for your experimental conditions If you use a perfu...

Страница 18: ...m ALA please follow these hints Always use the LIMITER Do not set the LIMITER to more than 50 for a longer time since the HPT 2A will melt if operated at more than 5V If in doubt measure the output vo...

Страница 19: ...al displays 3 1 2 digits XX X C temperature of SENSOR A or B or XX X V voltage at power output COMMAND INPUT analog input 10 mV C via BNC connector Set value control digital control range up to 60 0 C...

Отзывы: