User Manual
XLP 604
Parameter
Function
System
>
Print Control
>
Temp.
reduction
Sets the correction factor for the temperature compensation.
The higher the selected setting, the greater the reduction of
the driving power when the print head temperature rises.
Table 15: Parameters for setting the temperature compensation.
80
TR=0
TR=20%
TR=40%
60
100
%
0
26
54
°C
Print head
temperature
Drive performance
print head
TR = Value of parameter "Temp. reduction"
Fig. 43: With the parameter
System
>
Print Control
>
Temp. reduction
activated, the driving power of the print head – and
therefore indirectly the print contrast – are reduced. Reduction starts at a temperature of 26°C. The maximum value is
maintained at 54°C and above.
Readout example
:
The printing layout contains a lot of black areas. For this reason, the temperature reduction is activat-
ed with 40%.
►
System
>
Print Control
>
Temp. reduction
= 40%.
Now, if the print head temperature rises above 26°C, the driving power will be reduced automatically.
Reading out the diagram results in: With a given print head temperature of approx. 40 °C, the driving
power is reduced to approx. 80%; with a supposed print head temperature of 54 °C or above, it is re-
duced to 60%.