User Manual
XLP 604
50
100
150
200
mm
300
+3,0
mm
+2,0
+1,5
+1,0
+0,5
0
-0,5
-1,0
-1,5
-2,0
-2,5
-3,0
+1%
-1%
Distance punch to
print position
Max. misalignment of the
print position
Print position 1
Print position 2
Punch
Print direction
Label
Punch position
Max. misalignment at
print position 1 = 1,0 mm
Max. misalignment at
print position 2 = 2,5 mm
Fig. 6: Impression accuracy in printing direction, depending on the printing position.
Label sensor
• Standard:
Light-transmission
sensor for punched label material
• Option:
Reflex
sensor for label material with black marks on the bottom side
Setting range:
Setting range (mm)
Machine
Transmission
Reflex
XLP 604
2-60
2-60
Punch position and size see chapter
on page 13.
a
b
c
Label sensor
Punch
Label material
Fig. 7: Adjustment range of the label sensor.
Edition 2 - 12/2021
15
Product Description
Technical Data