Service Manual
ALS/XLS 20x/256/272
02/2019 | 01
115
Settings in the functions menu - syncronisation via Com1
From firmware version 2.52 on, the appropriate settings for both COM1 ports are done automati-
cally, if COM1 is selected as communication port (
MACHINE SETUP > Tandem synchron.
. = „Serial
Com1“). Additionally, the submenu for COM1 settings (
INTERFACE PARA >COM1 PORT
) is no longer
visible.
[100] Distance (A) between the dispensing edges of the two labelers
Settings on:
Menu >Submenu
Function
Setting
Master and Slave
INTERFACE PARA >EA-
SYPLUGINTERPR >
Interface
not
“Serial Com1” and
not
„Auto negotiation“
During tandem operation, Com1 is used
for communication between master and
slave machine. Therefore, the interface
function may not be set to „Auto negotia-
tion“ or to „Serial Com1“.
INTERFACE PARA
>COM1 PORT >
Baud rate
115 200
No. of data bits
the same setting on both machines
Parity
Stop bits
Data synch.
“None”
MACHINE SETUP >
Tandem synchron.
“Serial Com1”
Master
MACHINE SETUP >
Tandem Operation
“Master” or „FlipFlop master“
Tandem Distance
Set the distance [100A] between the dispensing
edges of the master and slave.
Slave
MACHINE SETUP >
Tandem Operation
“Slave”
[Tab. 15] Required settings for master and slave for tandem synchronisation via Com1.
A
Содержание ALS/XLS 204
Страница 2: ......
Страница 8: ...Service Manual ALS 20x 256 272 05 2019 8 Contents ...
Страница 110: ...Service Manual ALS XLS 20x 256 272 02 2019 02 110 ...
Страница 258: ...Service Manual ALS XLS 20x 256 272 02 2019 03 258 Repair 199 Removing the fan C A B C D ...
Страница 309: ......
Страница 310: ......
Страница 311: ......
Страница 312: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...