Service Manual
ALS/XLS 20x/256/272
02/2019 | 02
247
24 V PLC
The machine fans are driven by 24 V.
Unplug fan.
Measure voltage at the fan connector.
The following LEDs indicate that the PLC voltage appies properly:
– Yellow LED [187A] next to the 15pin D-Sub connector at the CPU connector plate (D901).
– Yellow LED [188A] close to the 10pin connector on the CPU board (D901).
[187]
LED (A) at the CPU board indicating the correct PLC voltage .
[188] LED (A) indicating the correct PLC voltage on the CPU board.
A
A
Содержание ALS/XLS 204
Страница 2: ......
Страница 8: ...Service Manual ALS 20x 256 272 05 2019 8 Contents ...
Страница 110: ...Service Manual ALS XLS 20x 256 272 02 2019 02 110 ...
Страница 258: ...Service Manual ALS XLS 20x 256 272 02 2019 03 258 Repair 199 Removing the fan C A B C D ...
Страница 309: ......
Страница 310: ......
Страница 311: ......
Страница 312: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...