Service Manual
ALS/XLS 20x/256/272
02/2019 | 01
37
Setting up
Prerequisites:
Support stand with a tube end providing the following
measures:
– Outer diameter: 60 mm
– Wall thickness: minimum 5 mm
The machines offer three attachment points for mount-
ing to the support:
– Rear side
Requires a fixing bolt to be mounted on the rear side
of the machine. A joint [18B] is used to attach the fix-
ing bolt to the support. Advantage: The machine can
be inclined both side to side and forwards and back-
wards.
– Side plate
Requires a flange [18A] to be mounted on the side
wall of the machine.
– Base plate
Requires a flange [18C] to be mounted on the base
of the machine casing.
WARNING!
Risk of injury from a tipping over support
stand.
When installing the machine on a sup-
port stand, make sure that it can not tip
over.
Fix the support stand onto the ground.
[18] Attachment points