114
Setting up tandem operation
Connecting the machines
[98] Cable layout for tandem interface cable (A7978)
Synchronisation over Com1
:
Connect the D-sub connector at either end of the tandem interface cable to the serial interface
of each machine [?A].
(Gen. 1 only) Connect the mini DIN 6 connector of the tandem interface cable to one of the two
machines, at the connection shown [?B].
Machines with Gen. 2 electronics don´t require the mini DIN connector to be connected.
Alternatively to the tandem interface cable, a standard null modem cable can be used.
Synchronisation over Ethernet
interface (peer-to-peer, that is direct connection without network):
Connect the (crossover) network cabel to the ethernet interface [?C] on both machines.
[99] Connections for the tandem interface cable (A; B).
If both machines are connected to a network, standard (1:1) network cables are required for
connection.
brown
yellow
metal cover
or
metallized
plastic
cover
metal cover
or
metallized
plastic
cover
shielded
cable
UL style
white
brown
green
yellow
brown
green
white
yellow
blue
blue
Steckseite
Lötseite
CN1A
SUB-D9 connector male
1
2
3
4
5
6
7
8
9
Steckseite
Lötseite
CN2A
SUB-D9 connector male
1
2
3
4
5
6
7
8
9
R1
2k2
CN3
use half of AK3233 (Reichelt Elektronik)
6
4
2
1
3
5
R2
2k2
A
B
C
Содержание ALS/XLS 204
Страница 2: ......
Страница 8: ...Service Manual ALS 20x 256 272 05 2019 8 Contents ...
Страница 110: ...Service Manual ALS XLS 20x 256 272 02 2019 02 110 ...
Страница 258: ...Service Manual ALS XLS 20x 256 272 02 2019 03 258 Repair 199 Removing the fan C A B C D ...
Страница 309: ......
Страница 310: ......
Страница 311: ......
Страница 312: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...